MOTOR MANUFACTURER · Fujian, CHINA

Dayou Motor

Fujian Dayou's industrial catalogue contains both a GOST-oriented ANP induction-motor family and an MVF aluminium motor built for variable-frequency operation with a separate rear cooling fan. ANP itself has different aluminium and cast-iron frame/power limits. A buyer should choose the installation standard, enclosure material and speed-control duty first, then request one selected code's dimensions, winding and test sheet; the broad catalogue ranges cannot be combined into a single motor.

LocationFujian, China
Published catalogue2 product series
Motor families1 represented

DAYOU · STANDARD MOTOR OR INVERTER DUTY

Dayou industrial motors: choose GOST ANP or forced-cooled MVF

Explore the published range ↓

01 / START WITH THE DUTY

ANP serves a fixed-speed GOST brief; MVF addresses inverter operation

ANP: GOST-market three-phase induction motor

The manufacturer's ANP page identifies a three-phase GOST-oriented range for fans, pumps, compressors and other machinery. It separates cast-iron frames H56–355 with a stated family power range of 0.75–315 kW from aluminium frames H56–132 with 0.18–11 kW. The page lists 50 Hz, 220/380 V or 380/660 V options, IP55, F insulation, IC411 self-fan cooling and S1 continuous duty as standard family characteristics. The top power is not an aluminium-frame rating and the voltage connection must be taken from the chosen winding.

Confirm before ordering Provide the required GOST mounting/dimension convention, selected frame material and size, driven load, kW and speed, supply and connection, shaft/flange, terminal-box orientation and ambient. Ask for the exact ANP code, IEC/GOST interchangeability drawing where relevant, nameplate, efficiency/test sheet and availability of optional heater or thermal protection.

View ANP GOST three-phase induction motors →

MVF: aluminium inverter-duty route

The company's MVF page describes a three-phase aluminium inverter motor with a separate forced-cooling fan, a published 20–100 Hz motor frequency range and 400 V rated supply. That separate fan matters when the driven shaft slows, because shaft-mounted cooling alone may fall with speed. The short public page does not supply a frame-by-frame torque envelope, fan supply, thermal limit or approved converter pairing.

Confirm before ordering State base and minimum/maximum process speed, constant- or variable-torque load, duration at low speed, converter output and cable length, fan auxiliary supply, bearing and insulation needs, mounting and ambient. Request the selected MVF's torque-speed/temperature curves, cooling fan wiring and tested converter configuration.

View MVF aluminium variable-frequency induction motor →

Other Dayou programmes are separate procurement scopes

The same company catalogue also groups IEC induction, brake, hydraulic, compressor, new-energy-vehicle and rolling-door motors. These are not interchangeable ANP or MVF variants. The buyer should name the actual equipment and application rather than assuming that one manufacturer's umbrella range grants all features to one offered motor.

Confirm before ordering If the project needs a brake, vehicle traction, door drive or hydraulic assembly, request that family's dedicated model, controls, interface and approvals rather than adapting an ANP or MVF quote by name.

02 / MAKE QUOTES COMPARABLE

A standard and a speed range do not replace a duty calculation

Which mechanical standard controls fit?

Confirm machine origin, GOST or IEC frame and mounting, foot/flange dimensions, shaft height and diameter, rotation and terminal-box position. Dayou lists both GOST and IEC product groups; a similarly named kW and pole count do not prove physical interchangeability.

Which winding and connection are being ordered?

The ANP page gives 220/380 V and 380/660 V as family options and describes different star/delta connections by power. Specify actual site voltage, frequency, start method and protection, then request the selected motor's nameplate and terminal drawing. Do not apply a family-level connection rule to an unconfirmed code.

What happens at the slowest inverter speed?

For MVF, provide the load-torque curve and time at low frequency; request continuous and peak torque allowance, separate fan power/control and temperature-rise evidence for the proposed frame. The public 20–100 Hz statement is a frequency band, not a guarantee of constant rated torque throughout it.

What site conditions alter the standard sheet?

State ambient, altitude, water or dust exposure, vibration, condensation, heater and thermal-sensor requirements. The ANP page's -15 to +40°C and up-to-1,000 m reference should be checked against the actual installation and selected enclosure.

03 / READ THE CATALOGUE LITERALLY

Keep construction, power range and cooling configuration linked

Do not join aluminium and cast-iron limits

ANP's headline H56–355 / 0.18–315 kW span is made from two construction ranges. The maker's own text caps its aluminium-frame programme at H132 and 11 kW, while the cast-iron programme extends to H355 and 315 kW. Select housing material with the frame and power, not after them.

IC411 and separate-fan cooling are different

ANP lists IC411 self-fan cooling for the standard family. MVF explicitly adds a rear forced-cooling fan for speed control. If a VFD is used on a standard ANP motor, a buyer must not assume the MVF cooling or low-speed thermal capability is present.

Option selection changes the drawing

Dayou lists an optional thermal protector, anti-condensation heater and terminal-box position choices for ANP, with grease fittings on larger frames. Request a revisioned drawing and bill of materials showing which options are included in the quoted code; do not infer they are standard on all frames.

04 / WHAT THE SOURCES PROVE

The company identity is public; each motor still needs its own approval packet

Independent legal-name cross-check

Fujian's public technology-enterprise list names 福建大酉新能源电机科技股份有限公司 in Fu'an. This corroborates the company identity and location at the list date. It does not verify the rating, energy class or destination-market approval of an ANP or MVF motor.

Site data is useful but family-level

The manufacturer's ANP page supplies separate construction ranges and standard environmental/supply conditions; the MVF page gives its forced fan and frequency concept. Neither is a complete model matrix. Ask for a selected serial-numbered nameplate, datasheet, test results and any applicable market documents before issuing a purchase order.

Published motor range

2 series

Company information

Company name
Fujian Dayou New Energy Motor Technology Co., Ltd.
Chinese registered name
福建大酉新能源电机科技股份有限公司
Region
Fujian, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.

LinkedInFacebookXWhatsAppEmail