YFB: transformer cooling fan
The manufacturer's YFB page describes a totally enclosed, surface-cooled three-phase induction motor for transformer fans, with 4–16-pole family options, standard 380 V/50 Hz supply, IC410 cooling and S1 duty. It lists a -40 to +75°C working-environment range and IP55 family protection. These are series-level conditions; a selected frame, winding and temperature rise still need a current sheet.
Confirm before ordering Provide the transformer cooler or fan maker and assembly code, required airflow and fan curve, shaft/flange and impeller interface, mounting orientation, ambient minimum/maximum, sun/rain exposure, 380 V supply and starting arrangement. Request the exact YFB variant, drawing, temperature-rise and noise data.
View YFB transformer cooling-fan motor →
YFL: cooling tower or evaporative cooler
The catalogue's cooling-fan YFL family is stated as frame heights H80–355 mm and a broad 0.55–375 kW programme, with 2–16 poles, IC410, S1, IP55 and a -15 to +40°C standard environment. The page highlights outdoor water resistance, low noise and reduced fan obstruction. A broad programme range does not establish that any one frame can achieve its highest listed power or all pole counts.
Confirm before ordering Send the fan curve, impeller diameter/inertia, operating airflow and static pressure, mounting frame, spray or condensation exposure, vibration and any inverter duty. Ask for the selected motor's thermal, efficiency, bearing and acoustic data at its actual speed.
Cold-room YFL and immersed BP are separate cases
The cold-room YFL text describes an unribbed surface, IC410, S1 and a -40 to +40°C environment for refrigerated fan duty. The BP transformer-oil-pump description instead says the motor operates immersed in transformer oil. Neither should be selected by copying the outdoor cooling-tower YFL drawing: low-temperature starting, sealing or oil compatibility change the acceptance questions.
Confirm before ordering For cold rooms, state minimum start temperature, defrost/washdown, condensate and fan mounting. For BP, give the transformer-oil specification, oil temperature, pump curve, immersed installation, seals, cable entry and compatibility/test requirements. Ask for separate drawings and material confirmation.