MOTOR MANUFACTURER · Jiangsu, CHINA

S&L Motor

Shuanglong Group Shanghai Explosion-proof Motor Yancheng Co., Ltd. manufactures industrial motors and lists standard low-voltage, high-voltage and explosion-protected families from its Yancheng operation. For an ordinary pump or conveyor replacement, first establish the voltage and fixed- versus variable-speed duty. The Y2VF high-voltage motor has a separately powered cooling fan; it is not a drop-in equivalent to a line-fed low-voltage YE motor. The manufacturer's YE4 and YE5 web pages repeat older YE3/IE2 specifications, so a buyer should obtain the exact offered motor's current efficiency report and nameplate before treating the series label as a verified rating.

LocationJiangsu, China
Published catalogue4 product series
Motor families1 represented

SHUANGLONG · INDUSTRIAL INDUCTION MOTORS

Shuanglong Motor: separate high-voltage VFD duty from low-voltage efficiency claims

Explore the published range ↓

01 / START WITH SUPPLY AND SPEED CONTROL

A high-voltage VFD project and a low-voltage replacement need different evidence

Y2VF for a variable-speed high-voltage machine

The manufacturer's Y2VF page identifies 3, 6 and 10 kV options, IC416 forced-air cooling and a separate axial fan. It describes constant-torque operation over 5–50 Hz and constant-power operation over 50–100 Hz at family level. These ranges do not confirm that every frame, load or site drive can run continuously at every point. For a large fan, pump or conveyor, check the torque-speed curve, drive output and cooling supply together, especially at low speed when a shaft fan would be inadequate.

Confirm before ordering Send the existing motor's rated voltage, kW, poles, mounting, shaft/load inertia, driven-machine torque curve, operating frequency profile, inverter output waveform, cable length and site altitude. Request the exact Y2VF frame's permitted speed/torque envelope, independent-fan supply, bearing/insulation measures and dimension drawing.

View Y2VF high-voltage variable-frequency motor →

YE2/YE3 for an ordinary low-voltage line-fed replacement

The official combined YE2/YE3 page describes a totally enclosed, fan-cooled three-phase induction motor with selectable B3, B5, B35, V1, B14 or B34 mounting. That family-level list is useful for narrowing a mechanical replacement, but the visible specifications identify YE2 and IE2 rather than a separate YE3 performance table. A buyer replacing a regulated high-efficiency motor needs the offered model's own efficiency data instead of assuming the heading establishes it.

Confirm before ordering Provide the present nameplate, supply and starter, shaft height, flange/foot dimensions, load cycle and ambient. Ask for a model-specific 50 or 60 Hz performance sheet, mounting drawing and measured efficiency at the required duty.

View YE2/YE3 high-efficiency induction motor →

YE4 or YE5 when efficiency is a purchase requirement

Shuanglong lists separate YE4 and YE5 catalogue entries, but both pages currently repeat the same 'Model: YE3 80~355' heading detail and IE2 efficiency text. The labels alone therefore cannot support a model-specific IE4/IE5 claim or an energy-saving/payback calculation. Compare a dated tested-efficiency sheet for the exact pole count and rating against your load hours and tariff before upgrading.

Confirm before ordering State the target efficiency standard, power/pole count, annual hours and measured load profile. Request the precise YE4 or YE5 model code, rated voltage, certified efficiency values, test method, current certificate scope and compatible frame drawing. Do not buy on a family name or an unsupported payback estimate.

View YE4 high-efficiency induction motor →

02 / RESOLVE THE PUBLISHED CONTRADICTIONS

The exact model sheet matters more than a series heading

YE4 and YE5 share old IE2 copy

The two official pages have distinct YE4 and YE5 titles but repeat a YE3 model field, IE2 efficiency designation and much of the same low-voltage detail. Even the YE2/YE3 combined page supplies a YE2 model field. This profile treats these as catalogue navigation, not proof that a quoted unit satisfies a specific efficiency class. Ask the supplier to reconcile the actual nameplate, dated datasheet and test or registration record.

Y2VF cooling is part of the drive system

The Y2VF product description calls for a separate axial fan, while its series title says totally enclosed fan-cooled and its specification table lists IC416. Confirm the auxiliary fan's electrical source and interlock with the inverter, the loss of cooling at low speed, and any bearings or insulation needed for the drive waveform. Do not substitute a line-fed motor's temperature limit or a generic variable-frequency claim.

Explosion protection is a different quotation path

The company also sells separate explosion-protected low- and high-voltage families. The four existing MotorSourcing product cards linked from this page are standard YE and Y2VF families, not a certificate for a hazardous area. If the installation has gas or combustible dust, provide the area classification and request the offered motor's exact Ex marking, certificate, temperature class and installation conditions before selection.

03 / MAKE THE QUOTATION COMPARABLE

Send the mechanical interface and duty, then verify the actual offered unit

Shuanglong's company description says the factory uses rotor balancing, high-voltage insulation impregnation and outgoing motor tests. These are manufacturer statements, not a third-party audit of the offered motor. A useful RFQ turns them into acceptance documents for the particular application.

Define the driven machine

Provide pump/fan/conveyor/compressor type, starting method, load torque and inertia, required speed range, starts per hour, running hours and the existing motor's nameplate and GA drawing. State whether the job is a drop-in retrofit or a new drive train.

Specify the electrical and thermal envelope

Record nominal and tolerance voltage, frequency, poles, drive topology, cable length, ambient, altitude, enclosure and cooling. For Y2VF, require auxiliary-fan supply, interlocks and the supported continuous operating envelope. For YE4/YE5, require exact-model efficiency data rather than a website family label.

Agree on inspection and documents

Ask for the signed dimensional drawing, performance curve, nameplate, insulation and temperature-rise evidence, factory test report, bearing arrangement, vibration limit and installation instructions. Where hazardous-area use is involved, add the certificate for the exact supplied suffix and site classification. Compare bids only after these documents describe the same duty.

Published motor range

4 series

Company information

Company name
Shuanglong Group Shanghai Explosion-proof Motor Yancheng Co., Ltd.
Chinese registered name
双龙集团上海防爆电机盐城股份有限公司
Region
Jiangsu, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.