02 / MATCH THE FAN TO THE AIR PATH
Axial, centrifugal and detachable-blade designs do different jobs
AC permanent magnet: start with the appliance supply
The manufacturer's JYF-02-3 is an inner-rotor AC permanent-magnet motor shown with a detachable fan, while JYF-03-2.5 is an outer-rotor axial-fan design. The JYF-03-2.5 table gives AC100–240 V, 0.08 A, 3 W maximum, 1,650 rpm ±10%, 3.40 cubic metres per minute and 36 Pa. Those are one catalogue entry's stated values, not a guarantee at a buyer's duct pressure or a rating for JYF-02-3, whose airflow and speed fields say they depend on the load.
Confirm before ordering Send mains voltage/frequency, available space, fan diameter, duct impedance, target airflow at static pressure, thermal ambient and electrical isolation requirements. Ask for the exact JYF impeller and connector, measured operating curve in the appliance and a current-revision safety file.
BLDC axial: airflow through a short path
ZWF-33-110-B is listed as a 12 V outer-rotor axial fan with PWM or voltage speed control and tachometer output. Its row states 0.2 A, 2 W maximum, 2,300 rpm ±150, 2.10 cubic metres per minute and 45 Pa. At 12 V, 0.2 A implies 2.4 W input, so the current and stated maximum-power fields need reconciliation; do not treat them as a verified common operating point. Neighbouring ZWF-33-110-D/E pages are separate variants. A restrictive grille can change delivered volume sharply.
Confirm before ordering Define inlet and outlet geometry, system resistance, minimum voltage at the fan, PWM frequency and logic levels, tach pulses/connector pinout, acoustic limit, orientation and fault response. Ask for a corrected electrical rating, a flow-versus-pressure curve and a sample tested behind the actual grille.
BLDC centrifugal: pressure and scroll geometry matter
ZWF-33-100 is a separate inner-rotor centrifugal design, also listed for 12 V PWM/voltage control with tach feedback. Its row states 0.104 A, 2 W maximum, 1,950 rpm ±10%, 1.00 cubic metre per minute and 45 Pa. The same 45 Pa figure as the axial entry does not make the two interchangeable: their housings, flow paths and resulting fan curves must match the machine.
Confirm before ordering Provide scroll or duct drawing, outlet orientation, back-pressure range, mounting bosses, wiring clearance and continuous duty. Compare both candidates on the same installed system curve rather than on a single headline air-pressure value.