01 / START WITH THE DRIVEN LOAD
An HVAC fan, a machinery shaft and a starting load need different evidence
Outdoor or indoor air-conditioning fan
The company's AC catalogue separates indoor commercial-unit motors from outdoor-unit fan motors. The outdoor MLA table labels output in watts and lists examples from 140 W to 700 W, with different pole counts and supply combinations. Its DC catalogue separately lists brushless fan drives: one outdoor DC Series row is 1.0 kW at DC 280–340 V and 900 r/min. A brushless unit needs its matching electronic control; the DC bus figure must not be read as an AC mains rating. Fan diameter, impeller inertia, airflow resistance and mounting govern selection as much as nameplate power.
Confirm before ordering Send indoor/outdoor placement, fan curve or airflow/static-pressure duty, impeller diameter and inertia, supply and controller details, running speed, shaft direction, bracket drawing, ambient temperature and expected cycles. Ask which exact AC or BLDC row is offered and for the matching controller or capacitor specification.
View Single-phase capacitor-run induction motor →
Three-phase industrial machine
The published machinery table groups 0.75, 1.5 and 2.2 kW four-pole motors, but voltage and speed vary by exact model and 50/60 Hz row. For example, the 0.75 kW 4715BF entry is shown with 200 V at 50 Hz and 200/220 V at 60 Hz, with corresponding 1400 and 1690/1710 r/min figures. It would be wrong to turn all rows into a universal 380 V specification. Check the offered variant against the machine's torque curve, starter, frame and shaft fit.
Confirm before ordering Provide required shaft torque across startup and running, duty cycle, grid voltage/frequency, starter or inverter, frame/foot dimensions, shaft and key, rotation, protection and temperature limits. Request the exact model code, drawing and test data for the proposed supply.
View Three-phase induction motor →
Resistance-start single-phase machinery
The YU catalogue is a different starting arrangement for air-pressure equipment and agricultural machinery: a centrifugal switch disconnects the start circuit. One 200 W row is published for 100 V at 50/60 Hz and another for 220 V at 50 Hz. Their speed and dimensions differ. This is neither a generic condenser-fan replacement nor proof that the unit will accelerate every compressor load.
Confirm before ordering Specify locked-rotor and loaded-start torque, pressure at restart, supply sag, switching frequency, run duty, capacitor and switch arrangement, enclosure and shaft coupling. Obtain the exact YU drawing and starting-performance evidence before selecting a substitute.
View Resistance-start induction motor →