01 / START WITH THE MACHINE
Four catalogue branches, four different purchasing decisions
YVF2 — speed set by an inverter
Shuda's YVF2 page gives an 80–315 mm frame-height and 0.55–200 kW family envelope, a 50 Hz base frequency, a stated 3(5)–100 Hz frequency span and IC416 independent-fan cooling. These are family limits, not a promise that every frame delivers rated torque across that entire span. The independent fan matters for low-speed operation where shaft-mounted ventilation would fall away.
Confirm before ordering Send the load-torque versus speed curve, lowest continuous speed, inverter output and switching frequency, cable length, start/stop rate and ambient. Request the exact frame's torque/temperature limits and independent-fan supply before choosing a gearbox or drive setting.
View YVF2 variable-frequency three-phase induction motor →
YEJ2 — a defined stopping or holding task
The YEJ2 brake-motor page lists an 80–225 mm frame range, 0.55–45 kW family output, F insulation and IP54/IP55 alternatives. It describes a half-wave rectifier and quick braking, but does not give a model-by-model brake torque, response time or vertical-load approval. A brake-equipped motor should be selected as an assembly, not treated as a standard induction motor with an unspecified accessory.
Confirm before ordering State moving inertia, required stop time, stops per hour, orientation, power-loss behaviour and any suspended load. Require the specific brake torque, coil/rectifier voltage, release time, manual-release provision and duty rating; perform a separate safety assessment if people or a suspended load are at risk.
View YEJ2 electromagnetic brake motor →
YB2 — atmosphere classification before a quote
The maker's YB2 page gives a 63–280 mm frame and 0.12–90 kW family span, IP55 and IC411. It discusses mining Group I and industrial Group II uses, but a broad catalogue statement cannot establish the explosion-protection marking, temperature class or current certification of a proposed serial-numbered motor. Site classification and the exact certified variant decide suitability.
Confirm before ordering Provide the hazardous-area classification, gas or dust group, temperature class, ambient range, installation country, cable-entry method and inverter use. Request the current certificate, exact model/marking schedule and installation instructions; do not infer mine or petrochemical suitability from the YB2 series name alone.
View YB2 flameproof three-phase induction motor →
MS — pump-oriented mechanical fit
Shuda describes the MS aluminium-frame family as developed for pump matching, with cast-iron front flange and rear end cover. Its public page lists 380/400/415 V and 50/60 Hz alternatives, continuous S1 duty, F insulation, and IP54/IP55 casing options with an IP55 terminal box. The page's IE2/IE3 wording is a family-level claim; it is not an efficiency certificate for any selected frame or destination market.
Confirm before ordering Send pump curve and starting method, coupling/shaft and flange drawing, liquid-system duty, supply and frequency. Ask for the exact model's dimensional drawing, tested efficiency at the ordered rating and the applicable casing/terminal-box IP combination.
View MS high-efficiency aluminium-housing motor →