01 / MATCH THE SUPPLY AND DUTY
Choose the voltage class before discussing efficiency or frame size
Y2 for an ordinary low-voltage replacement
Lixin describes Y2 as a general-purpose, enclosed fan-cooled squirrel-cage series for machinery such as pumps, fans and compressors in non-explosive, non-corrosive locations. The official page specifies 380 V/50 Hz baseline, S1 continuous duty, F insulation, IP54/IP55 alternatives and IC411 cooling, then provides extensive historical model tables. It also uses an older EFF2 label; neither that label nor a table row establishes compliance with today's destination-market efficiency rule.
Confirm before ordering Send the existing nameplate, frame and mounting drawing, shaft/coupling dimensions, pump or fan curve, supply, starting method, ambient and desired efficiency class. Ask for the current exact-model sheet and test report before selecting a Y2 replacement or claiming an energy saving.
View Y2 three-phase induction motor →
YE4/YE5 when verified efficiency is the purchase driver
The maker separately markets YE4 and YE5 higher-efficiency induction families and gives a 380 V/50 Hz, IC411, S1 baseline on the combined page. The text refers both to GB 18613-2020 and inconsistent 'GB/T18163-2020' wording, while also mixing IE and domestic grade language. Treat the combined page as a catalogue route; do not infer a certified efficiency for a particular pole, kW, voltage or country from its heading.
Confirm before ordering Ask for the offered full model code, rated efficiency and loss-test method at the ordered voltage/frequency, current applicable standard, laboratory report, price premium and annual operating hours. Compare lifetime energy using the real load factor and duty, not only nameplate efficiency.
View YE4/YE5 high-efficiency induction motor →
YKK at 6 kV or 10 kV for a high-voltage plant drive
The YKK pages describe enclosed box-frame squirrel-cage motors with a top air-to-air cooler, F insulation, S1 duty, IC611 cooling, IMB3 mounting and IP44/IP54 choices. The 6 kV and 10 kV pages have separate voltage classes and model tables. Their repeated process claims do not establish an individual rotor, bearing or insulation configuration. One 6 kV table even puts a 750-rpm value next to a 2-pole model heading, so exact speed and drawing must be confirmed in the signed quotation.
Confirm before ordering For either voltage, give the single-line diagram, starting voltage dip limit, load torque/inertia, protection scheme, cooler airflow, site altitude/ambient and transport envelope. Request exact rotor/bearing choice, thermal and vibration tests, cable/terminal arrangements and final certified drawings. Do not substitute a 10 kV row into a 6 kV inquiry.
View YKK 6kV high-voltage induction motor →