MOTOR MANUFACTURER · Jiangsu, CHINA

Shangyang

Jiangsu Shangyang publishes both YE4 general-purpose induction motors and YVF2 inverter-duty motors. They answer different procurement briefs: a fixed-speed replacement is mainly an electrical and mechanical match; a variable-speed drive also needs the working speed range, load torque and low-speed cooling confirmed for one actual model.

LocationJiangsu, China
Published catalogue2 product series
Motor families1 represented

SHANGYANG · INDUSTRIAL INDUCTION MOTORS

Shangyang motors: choose YE4 for fixed speed or YVF2 for inverter duty

Explore the published range ↓

01 / FIRST DECISION

A pump replacement and a speed-controlled line need different briefs

YE4: start with the existing fixed-speed installation

Shangyang describes YE4 as a three-phase induction family for fans, pumps, machine tools, compressors and conveying machinery. Its public description says the installation dimensions follow IEC 60034; it does not provide a model-by-model dimensional schedule on that page. For a drop-in replacement, compare the old nameplate, frame, foot or flange pattern, shaft height and extension, supply and starter before treating the family name as equivalent.

Confirm before ordering Send the existing motor nameplate and dimensioned mounting photo. Ask for the offered YE4 model's drawing, exact rated output, voltage, frequency, poles, efficiency evidence, insulation and protection details. Confirm the driven load's starting and overload demands.

View YE4 industrial induction motor family →

YVF2: define the driven duty across the speed range

The maker positions YVF2 for operation with an electronic frequency converter, and its site gives 150–2750 rpm as a four-pole series illustration. That is not a promise that every size can supply rated torque continuously at both endpoints. A fan's falling torque, a conveyor's starting torque and a machine tool's speed range can require different inverter, cooling and protection choices.

Confirm before ordering Provide the load-torque versus speed requirement, minimum continuous speed, maximum speed, acceleration and braking duty, inverter output, cable length and ambient. Request the chosen motor-and-drive combination's permitted torque-speed envelope and cooling method in writing.

View YVF2 variable-speed induction motor →

02 / INSTALLATION REALITY

Match the complete installation, not a catalogue headline

Mounting and shaft first

Before changing a motor on an existing machine, check the coupling or pulley, shaft extension, foot or flange dimensions, available terminal-box clearance and rotation direction. An IEC-referenced frame description does not establish that every shaft detail, enclosure or accessory matches the old installation. Ask Shangyang for the exact variant drawing before approving a replacement.

Cooling is a duty question for inverter operation

A motor driving a low-speed conveyor for long periods may receive less shaft-fan airflow than it does near nominal speed. Do not assume the YVF2 catalogue's broad speed statement establishes continuous low-speed thermal capacity. Specify the actual torque and dwell time at each operating point and have the maker identify any separately powered fan or derating requirement.

Keep hazardous-area motors separate

The same manufacturer also lists YBX and YBBP explosion-protected families. Ordinary YE4 and YVF2 pages are not evidence of a hazardous-area approval. For gas or dust zones, provide the site classification and require the certificate and nameplate for the precise protected model; do not substitute a standard motor because it has a similar frame.

03 / BUYER CHECKLIST

Make the competing offers describe the same motor and duty

What should the first inquiry include?

Identify the driven machine, load type, existing motor plate or new shaft requirement, mains supply, operating hours, starting method, mounting drawing, enclosure exposure and destination. For a speed-controlled project include the VFD model and a speed/torque schedule rather than only the desired maximum rpm.

Which documents make a quotation comparable?

Request the full model code, variant-specific technical sheet and drawing, efficiency rating at that output and pole count, rated current, insulation/protection, cooling, permissible drive operation, included accessories, test scope and delivery terms. Separate a standard catalogue option from a custom drawing-based build.

What should be checked at handover?

Agree nameplate and dimensions against the approved drawing, terminal connections, insulation checks, rotation, current and temperature at the actual operating load. For YVF2, test more than one operating speed and compare the results with the agreed drive and cooling configuration.

04 / VERIFIED SCOPE

The enterprise and two product families are documented; the ordered variant still needs proof

Company identity and manufacturing project

Shangyang's own company page identifies 江苏上阳电机有限公司 and describes motor development, production and customization. A Taixing municipal environmental-approval list independently names the same legal entity in a motor manufacturing project. That public approval corroborates identity and a project record; it is not evidence of realized annual output, an inspected production line or a current certificate.

Catalogue limits

The official YE4 page gives applications and an IEC installation-dimension claim, while the YVF2 catalogue description gives a four-pole speed illustration. Neither page resolves the exact ordered frame, shaft, efficiency test result or permitted continuous torque at every speed. Those are model-specific quotation and acceptance items.

Published motor range

2 series

Company information

Company name
Jiangsu Shangyang Motor Co., Ltd.
Chinese registered name
江苏上阳电机有限公司
Region
Jiangsu, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.