MOTOR MANUFACTURER · Jiangsu, CHINA

Shilin

Shilin's YE5 serves ordinary machinery; YBBP5 is an inverter-duty protected family. Efficiency is not hazardous-area approval. Send the machine load and site classification, then require the exact model's drawing, cooling limits and current certificate.

LocationJiangsu, China
Published catalogue2 product series
Motor families2 represented

SHILIN · INDUSTRIAL AND PROTECTED MOTORS

Shilin motors: distinguish YE5 efficiency from YBBP5 hazardous-duty drive

Explore the published range ↓

01 / MACHINE AND AREA

The operating environment determines which family to evaluate

YE5 for an ordinary, fixed-speed machine

The maker describes YE5 as a self-fan-cooled IC411 three-phase induction family for pumps, fans, compressors, conveyors and other general machinery. Its official page claims top-tier efficiency under named standards, but provides no readable exact-model test table. For a normal plant location, compare load, supply, pole count, frame, mounting and actual tested efficiency at the quoted output instead of selecting by the YE5 label alone.

Confirm before ordering Provide the existing plate or load curve, mains supply, starter, frame and shaft drawing, duty cycle and ambient. Request the specified model's rated data, current, efficiency report, dimensions and cooling limits. If the motor will run on a VFD, ask whether this exact variant is approved for that duty.

View YE5 three-phase induction motor family →

YBBP5 for a classified area with speed control

The separate YBBP5 page describes a protected inverter-duty motor with S1 duty and IC416 independent cooling. It distinguishes gas and combustible-dust contexts and describes different frequency zones for open-loop control. The printed Ex markings on that page are not consistently typeset, so they cannot establish which atmosphere, zone or temperature class a particular offered unit is approved for.

Confirm before ordering Supply the site's gas or dust classification, temperature limit, VFD model and required torque-speed points. Require the exact unit's valid explosion-protection certificate and nameplate, matching cable-entry and accessory scope, plus the continuous torque-speed and independent-fan supply instructions.

View YBBP5 flameproof inverter-duty motor →

02 / MORE THAN A MOTOR

For a hazardous location, the installation must match the certified configuration

Match the certificate to the offered build

The manufacturer's family page lists several gas and dust examples, but a family description is not a certificate for every frame, pole count and accessory. Check the legal holder, certificate number, marking, temperature class, valid scope, enclosure, terminal arrangement and any installation conditions against the order code and the actual site. Do not substitute an ordinary YE5 even when the output and frame are similar.

Specify drive, cooling and protective devices together

YBBP5's official description names a separately powered cooling fan and variable-frequency operation. A purchaser should define the lowest sustained speed, highest speed, load torque, overload time, VFD switching conditions, temperature sensing and independent-fan supply. The maker's broad frequency description does not prove rated torque or permissible heating at every operating point of an unspecified model.

Do not infer a mine approval from a gas or dust example

The YBBP5 page explicitly distinguishes its stated industrial gas and dust contexts from coal-mine methane conditions. If the job is underground or has mixed hazards, stop at the site classification and ask for an exact approved model and current certificate. Marketing use in chemical or mining industries is not a substitute for the required marking.

03 / COMPARABLE OFFERS

One procurement brief should tie the machine, zone and offered model together

What should a buyer send?

Send the machine and old motor identification, actual mechanical load, mounting drawing, supply and VFD, speed range, duty hours, ambient and cooling constraints. For a hazardous location, add the formal gas or dust area classification, temperature group and any earthing, cable-gland or sensor requirements.

Which proposal details are essential?

Compare the full model code, exact electrical and dimensional sheet, rated current and efficiency evidence, cooling and permitted VFD envelope, included fan/sensors, spare-parts boundary, tested configuration and delivery terms. For YBBP5 include a matching valid Ex certificate and a readable nameplate marking.

What should be demonstrated before acceptance?

Check the actual unit against the approved drawing and documents. Verify rotation, current, temperature and vibration at representative loaded points; on YBBP5 include low-speed operation, independent fan, thermal protection and the certified cable-entry arrangement. Agree the witness and records before order placement.

04 / EVIDENCE STATUS

Company identity is cross-checked; model approvals remain order-specific

Which company is this?

The official site names 江苏士林电机有限公司 in Yixing and lists induction and explosion-protected motor families. A Jiangsu public technology-enterprise list independently names the same legal entity in Wuxi. The public list is historical identity evidence, not a current motor certificate or proof of every claimed plant capability.

Why are company-size and Ex claims bounded here?

The current official homepage displays inconsistent year and headcount figures, while its YBBP5 page has malformed protective markings. This profile does not repeat those figures as verified facts or assign an Ex designation to an unspecified model. Request original, current documents for the selected frame and destination market.

Published motor range

2 series

Company information

Company name
Jiangsu Shilin Motor Co., Ltd.
Chinese registered name
江苏士林电机有限公司
Region
Jiangsu, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.