MOTOR MANUFACTURER · Tianjin, CHINA

Shenchuan

YEJ adds an electromagnetic stopping brake; YVP is built for inverter speed control. Shenchuan publishes separate sheets. Decide whether the machine needs a safe stopping interface, a speed envelope, or a separately engineered combination.

LocationTianjin, China
Published catalogue2 product series
Motor families2 represented

TIANJIN · APPLICATION-SPECIFIC MOTORS

Tianjin Shenchuan: brake holding versus inverter speed control

Explore the published range ↓

01 / DEFINE THE MACHINE TASK

A holding brake and a variable-frequency drive solve different problems

YEJ: stopped position, brake release and load safety

The manufacturer's YEJ sheet describes a three-phase induction motor with a spring-applied, electrically released disc brake for machinery that needs quick stopping or position retention. Its sample table lists power by frame and synchronous speed, and a separate table gives brake torque and no-load brake time by frame. A table value measured without load cannot prove a vertical load is safely held or stopped at the buyer's duty.

Confirm before ordering Give shaft load and inertia, stop frequency, stopping distance or time, gravity/back-driving risk, brake supply, manual release need, emergency-stop category and required safety factor. Ask for a brake-torque and temperature calculation at the exact ordered frame, plus the wiring and maintenance instructions.

View YEJ three-phase brake motor →

YVP: torque and cooling across the requested speed range

Shenchuan's YVP sheet describes an inverter-fed induction motor with 380V, 50Hz reference supply, S1 duty and IP54 in its stated standard conditions. It discusses IC411 self ventilation and IC416 separately powered ventilation as different cooling methods. Its prose describes 10–70Hz constant-torque operation for one arrangement but does not map every frame, inverter or cooling choice to an identical continuous-output envelope.

Confirm before ordering Send the driven-machine torque-speed curve, minimum and maximum continuous speeds, VFD output, PWM cable length, load cycle, ambient, enclosure and shaft-bearing constraints. Require a frame-specific motor/VFD curve, cooling option, bearing-current measures and tests at the slowest loaded speed.

View YVP inverter-duty induction motor →

02 / WHEN BOTH ARE NEEDED

Do not treat YEJ and YVP as an automatically interchangeable brake-VFD package

The brake circuit is independent of the drive output

If the axis needs variable speed and stopping, specify whether the brake is only for parking or also for emergency stopping. Obtain a confirmed motor-plus-brake variant, brake coil voltage, rectifier and release delay, VFD stop sequence and mechanical load calculation. Feeding an electromagnetic brake directly from an unspecified inverter output is not a safe assumption.

A low-speed motor still produces heat

A self-ventilated motor loses shaft-driven airflow as speed falls. Where the YVP choice relies on independent ventilation, assign its separate power supply, failure monitoring and airflow to the machine integrator. Ask whether the selected brake package changes motor length, shaft extension, terminal box or protection rating.

03 / BUYER'S BRIEF

Specify stopping, thermal and mechanical acceptance before price comparison

What should be in a comparable quotation?

Ask for the complete order code and frame, motor and brake nameplate data, exact outline/shaft and mounting drawings, brake torque and release/reaction times under stated conditions, VFD and cooling compatibility, duty/ambient limits, wiring/rectifier diagram, accessories, spares and a factory test plan. Mark which published values are example rows rather than guaranteed order-specific figures.

Which tests belong at the machine site?

Verify direction, brake release and re-engagement, loaded stopping distance and temperature rise over the actual cycle. For YVP, record current, speed and winding/bearing temperature at minimum continuous speed and maximum load; check VFD faults and independent-fan loss response. A no-load brake-time table alone is not site acceptance.

04 / LIMITS OF THE PUBLIC RECORD

Historical engineering material needs current-order confirmation

Company and research-institute relationship

The company's own introduction says it was formed from the Tianjin Special Motor Research Institute. A public standards record independently names both organisations as historical co-drafters of a construction-equipment motor standard; that record is now withdrawn. It corroborates the relationship, not present certification of YEJ or YVP.

Published sheets are old and variant-specific

The available YEJ and YVP sheets are image-based historical catalogues. YEJ publishes frame-by-frame brake data but no calculation for this buyer's load. YVP gives standard conditions and cooling alternatives but no complete present-day motor/VFD matrix. Confirm current drawings, performance tests and any required market approvals for the exact quote before relying on either sheet.

Published motor range

2 series

Company information

Company name
Tianjin Shenchuan Electric Machine Co., Ltd.
Chinese registered name
天津神川电机有限公司
Region
Tianjin, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.