Brake motors
YXEJ electromagnetic brake motor series
ANHUI WANNAN ELECTRIC MACHINE CO.,LTD.- Power
- 0.18–200 kW
- Motor Type
- Three-phase induction with electromagnetic brake

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
Two details in Deli’s YEJ2 documentation can change a replacement decision: the 90S and 90L versions share the listed overall length but have different B3 foot spacing, and the brake section is IP23 even when the motor enclosure is specified to a higher IP option. Select the complete motor-and-brake assembly for the actual machine.
Dimensions below are in millimetres. The B3 drawing is foot-mounted without a flange; the separate B5 drawing is flange-mounted without feet. Confirm the ordered arrangement and manufacturing tolerances on the final drawing.
| Dimension | 90S | 90L |
|---|---|---|
| B3 transverse foot spacing A | 140 | 140 |
| B3 axial foot spacing B | 100 | 125 |
| B3 shaft centre height H | 90 | 90 |
| Shaft D × E | 24 × 50 | 24 × 50 |
| Key width F | 8 | 8 |
| Overall length L | 384 | 384 |
| B5 flange designation | FF165 | FF165 |
| B5 pitch circle M / register N | 165 / 130 | 165 / 130 |
Deli lists motor enclosure choices IP44, IP54 or IP55, while the brake section is listed as IP23. If the existing installation depends on a sealed motor enclosure, check the brake-end exposure as well. State water spray, dust and cleaning conditions and request the complete supplied assembly’s protection specification.
The listed 384 mm length for frames 90S and 90L describes the motor outline, not a service clearance. Send a photograph or layout of the adjacent guard and machine structure. Ask for the access needed to inspect, adjust and service the specified brake before fixing the motor position.
Give the driven inertia, operating speed, required stopping time, stops per hour and whether the brake must hold a stationary load. The public YEJ2 page does not supply a model-specific braking-torque or permissible braking-energy table. Ask for those ratings for the proposed brake; matching frame 90 and shaft dimensions does not establish stopping performance.
Request coil voltage, rectifier requirements, release and engagement times, and a connection diagram for the supplied brake. The published 50/60 Hz and 220/380 or 380/660 V options concern the motor supply; they do not identify the brake coil voltage. Include the existing control sequence and power-loss behaviour you require.
Identify B3 or B5, the motor winding and supply, the selected B or F insulation option, and motor plus brake protection ratings. Deli states continuous rated operation up to 1000 m altitude and 40°C ambient under its listed conditions. Repeated braking is an additional duty to specify, rather than something established by the continuous-running statement.
CATALOGUE OVERVIEW
Deli’s YEJ2 aluminium-housing brake motors list 50/60 Hz and 220/380 V or 380/660 V winding options. Motor enclosure options are IP44, IP54 or IP55, but the brake section is separately specified as IP23. This distinction matters when installing the assembly in a wet or dusty location. The source states continuous operation within 1000 m altitude and ambient temperature up to 40 °C.
Model / series reference: YEJ2
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details