AC induction motors
YE5 three-phase induction motor
ANHUI WANNAN ELECTRIC MACHINE CO.,LTD.- Power
- 0.75–375 kW
- Voltage
- 380 V

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
Moving from the 4 kW YE4-112M-4 to the 5.5 kW YE4-132S-4 changes the shaft and flange, not just the electrical load. The catalogue’s mounting matrix also stops listing B14 at frame 112. Check these boundaries before specifying a higher-power replacement for a gearbox, pump or compact machine.
Electrical values are the 380 V, 50 Hz four-pole rows. Dimensions refer specifically to the catalogue’s B35 foot-and-flange arrangement and are in millimetres; they are not B14 dimensions.
| Check | YE4-112M-4 | YE4-132S-4 |
|---|---|---|
| Rated output / speed | 4 kW / 1,460 rpm | 5.5 kW / 1,475 rpm |
| Rated current / torque | 8.3 A / 26.2 Nm | 11.4 A / 35.6 Nm |
| Shaft diameter × extension | 28 × 60 | 38 × 80 |
| Key width | 8 | 10 |
| Foot-hole spacing A × B | 190 × 140 | 216 × 140 |
| Flange pitch / register / outside diameter | 215 / 180 / 250 | 265 / 230 / 300 |
| Overall length L | 455 | 510 |
The mounting matrix marks these arrangements for frames 63–112 and leaves them unlisted in larger frame groups. A compact B14 gearbox connection therefore cannot be assumed to carry over to the 132-frame 5.5 kW example. Request a confirmed alternative assembly before selecting the larger motor.
V3 is marked for frames 63–112 and 132–160, but not for 180–280 or 315–355. V1 is listed across all four frame groups. Give the supplier the actual shaft direction and driven-machine loading; a vertical request without the mounting code leaves an important configuration undecided.
For frames 315–355, the table marks B3, B35 and V1, while B5 is unlisted. Do not select a flange-only arrangement from a small-frame illustration. The frame-specific mounting table and final assembly drawing should agree.
Both four-pole examples list a locked-rotor current ratio of 9.5. Multiplying by rated current gives about 79 A for the 4 kW motor and 108 A for the 5.5 kW motor under the catalogue conditions. These are screening calculations, not breaker settings: assess the actual supply, starting method, acceleration time and protection coordination.
The catalogue treats the right-side terminal box as standard unless the order states otherwise. Identify the viewing direction on the installation drawing and confirm any alternative position. The larger shaft and 55 mm longer B35 body already require a fit check; cable access can create a separate obstruction.
The comparison above is from the 380 V, 50 Hz table. A 60 Hz or alternative-voltage order needs its own rated current, speed and performance confirmation. The family’s availability of other supplies does not make the 50 Hz figures applicable unchanged.
CATALOGUE OVERVIEW
Wannan’s YE4 three-phase induction series is published with a 0.37–375 kW range and frame sizes 63–355. Its catalogue lists 380 V with other voltages by agreement, 50 Hz or 60 Hz configurations, IP55 protection and class F insulation. The manufacturer describes IC411 cooling and general industrial applications including pumps, fans, machine tools and conveying equipment. Select the exact pole count, mounting and operating supply from the model datasheet. Efficiency and certification statements in the source require confirmation against the specific offered motor.
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details