MOTOR MANUFACTURER · Hebei, CHINA

Hengshui Electric Motors

Hengshui Electric Motors' catalogue is broader than one efficiency series. Its removable-foot HuE is a mechanical replacement option; NEMA covers a different frame and supply system; YE4 targets fixed-speed efficiency, YVF2 inverter duty and YG mill rollers. Each needs a different inquiry.

LocationHebei, China
Published catalogue2 product series
Motor families1 represented

HENGSHUI · MULTIPLE MOTOR DUTIES

Hengshui Electric Motors: replace, vary speed or drive a roller

Explore the published range ↓

01 / FIVE REAL APPLICATION PATHS

Do not compare these families by kilowatts alone

HuE: inspect the removable foot arrangement

The company's HuE page says frames 63–280 can be changed among B3, B5 and B35 mounting by changing the foot arrangement. It also distinguishes sealed bearings through frame 180 from re-greasable open bearings at frame 200 and above. A replacement buyer should compare bolt circle, shaft height, terminal orientation, bearing access and coupling alignment, not infer that every bracket position fits an existing machine.

Confirm before ordering Provide old outline and mounting photos, required B3/B5/B35 arrangement, shaft and bearing load, maintenance access, 400 V/50 Hz or the site's actual supply. Ask for the exact HuE configuration drawing and bearing/seal schedule.

NEMA: a North American frame needs its own compliance check

The NEMA page lists frames 143T–449T, 60 Hz and voltage options of 230/460, 460 and 575 V, with 1.15 service factor mentioned for the family. A 400 V IEC-style motor is not automatically a mechanical or electrical substitute. Confirm the precise frame, enclosure, nameplate and relevant market approval for the ordered unit.

Confirm before ordering State destination, frame, shaft and base drawing, voltage/frequency, starts, load profile and required listing. Request an exact offered nameplate and valid approval scope rather than assuming the whole range shares one certificate.

YE4 versus YVF2: decide whether speed is fixed or controlled

The YE4 page includes separate 2-, 4-, 6- and 8-pole rows with different rated output and efficiency, while YVF2 has a distinct inverter-duty table. The highest efficiency in one YE4 row and the broadest speed claim for YVF2 cannot be joined into a single motor specification. For a pump or fan with a VFD, request the motor-drive operating envelope and cooling at minimum loaded speed.

Confirm before ordering Send process speed and torque points, VFD model, cable length, ambient and efficiency target. Ask for the exact pole/frame row, inverter insulation, bearing treatment, cooling and performance tests under the offered configuration.

View YVF2 variable-frequency motor →

YG: decide whether the roller is conveying or working

The maker's YG page expressly covers continuous S1 transfer rollers and short-time or intermittent work rollers in metallurgy. A work roller may see reversing, impact and repeated starts that a transfer roller's steady load does not. Define the actual cycle and temperature before quoting frame size.

Confirm before ordering Give roller diameter, line speed, material/ambient heat, impact and jam loads, starts/reversals, gearbox and duty timeline. Request a thermal calculation and the ordered bearing, sealing and cooling details.

02 / CONFIGURATION BOUNDARIES

Inverter duty and hazardous-area approval are separate decisions

Do not transfer a flameproof label across series

The official catalogue separately lists YBBP flameproof inverter, YBX flameproof fixed-speed and YFBX dust-protected families. They are not interchangeable approvals. Specify gas or dust classification, zone, temperature class, ambient, converter parameters and the exact current certificate schedule before purchase.

Different company-site versions give different scale figures

The manufacturer's newer Chinese site and older English site show markedly different employee and equipment counts. This profile does not repeat either as a current verified capacity. Assess today's factory capacity and lead time from a dated supplier response and visit or audit evidence.

A YE4 table is a row-by-row reference

The company's YE4 table varies rated power, speed and efficiency by pole count and frame. Use a specific row as a quotation reference, then obtain the current signed datasheet and test method. A series-level efficiency label or past company award does not establish performance of an unspecified order.

View YE4 three-phase induction motor →

03 / PURCHASE WITHOUT GUESSWORK

A one-page duty sheet prevents a wrong-family quotation

What should the buyer provide?

State application and load cycle, output and speed points, supply and VFD/starter, exact mounting and shaft drawings, thermal and contamination conditions, starts or reversals, hazardous-area classification if any, destination standard, required witness tests and annual quantity.

What should the supplier return?

Request the chosen family, complete model and pole/frame row, installation outline, nameplate and efficiency evidence, thermal/starting calculation, bearing and cooling design, active approvals for that configuration, routine/type-test schedule and delivery/commissioning responsibility.

Published motor range

2 series

Company information

Company name
HENGSHUI ELECTRIC MOTORS CO., LTD.
Chinese registered name
衡水电机股份有限公司
Region
Hebei, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.