MOTOR MANUFACTURER · Jiangsu, CHINA

Shuangyun Motor

Jiangsu Shuangyun publishes distinct motor paths for underground machinery, excavation equipment, conveyors and variable-frequency drives. Their catalogue ranges are not one interchangeable motor. Match the load and site classification first, then request the selected model's certified marking, drawing and duty data before a hazardous-area purchase.

LocationJiangsu, China
Published catalogue4 product series
Motor families2 represented

JIANGSU SHUANGYUN · HAZARDOUS-DUTY SELECTION

Jiangsu Shuangyun: select mine, conveyor and variable-frequency flameproof motors

Explore the published range ↓

01 / NOT ONE GENERIC FLAMEPROOF MOTOR

The machine duty separates four catalogue paths

YBK3 for general underground mechanical drive

The maker describes YBK3 as an underground coal-mine flameproof induction-motor series for general mechanical equipment. Its page prints 50 Hz, 380/660/1140 V supply variants, a 2.2–630 kW family span, S1 duty, IP55 and class F insulation. Those are series-level options, not one product's combination of voltage and power. The printed explosion marking has ambiguous characters, so it cannot establish a selected unit's exact protection category.

Confirm before ordering State site classification, the load torque-speed curve, required voltage connection, starting method, frame, cooling and mounting. Request the exact YBK3 code, nameplate and certificate matched to the ordered construction.

View YBK3 underground-mine induction motor →

YBU for a tunnelling or excavation-machine interface

The YBU page identifies an excavation-machine-specific path rather than a drop-in general-purpose YBK3. It lists 380/660 or 660/1140 V, 50 Hz, 55–200 kW across the range, S1, IP55, class H insulation, and B3/B5/B35 mounting options. The page says electrical and dimensional data can be designed to customer requirements; it does not give a complete fixed gearbox or mounting drawing.

Confirm before ordering Send the excavation machine's motor bay, coupling, shock/vibration duty, cooling path and selected supply. Require a model drawing, shaft/load limit, start and thermal tests, and the valid protection documents for that configuration.

View YBU excavation-machine flameproof motor →

YBS/DSB for conveyor or crusher auxiliaries

A separate manufacturer page places YBS/DSB with conveyors, transfer machines and crushers. It states 380/660 or 660/1140 V, 50 Hz, a 4–125 kW family span, S1, IP54, class F and B3 installation. That different enclosure and machine scope should not be silently substituted for YBK3 or YBU. No currently published MotorSourcing product card represents this exact series, so its details remain an RFQ route rather than a claimed stocked model.

Confirm before ordering Identify the driven conveyor or crusher, service factor, starting load, ambient dust/gas conditions, B3 footprint and required coupling. Ask for the selected YBS/DSB drawing and certificate.

02 / WHEN THE DRIVE IS VARIABLE-SPEED

YBBP needs a matched inverter, thermal envelope and certified installation

The maker lists YBBP separately from fixed-frequency mining and machine-specific models; a family power range alone cannot establish a safe variable-speed installation.

The printed range is only a catalogue envelope

The YBBP page lists 50 Hz base supply variants and 2.2–630 kW across the series, but gives no readable minimum continuous frequency, torque derating, inverter waveform limit or bearing-current protection schedule. Its statement that dimensions match YB3 is too broad to use as an installation drawing for a selected motor.

Protection marking requires original documents

Official pages render markings with inconsistent characters such as '1', 'I', 'L' and '2 BT4'. A buyer must not infer that one motor covers mine and industrial gas locations. Request the certificate number, issuing body, exact Ex marking, equipment group/category, temperature class, ambient range and wiring/accessory conditions for the quoted serial/model.

Use a complete motor-inverter operating schedule

Specify continuous and peak torque at each operating speed, acceleration, starts per hour, cable length, supply, output filter, independent fan if needed and winding thermal protection. Ask for a matched inverter parameter sheet and witnessed or traceable test results at the required duty rather than extrapolating from nominal 50 Hz data.

03 / ACCEPTANCE PACKAGE

Compare offers at the exact coded motor and installation level

Which site and machine are being approved?

Provide the hazardous-area classification and jurisdiction, installation location, driven machine, shaft and flange dimensions, speed/load profile, supply network, ingress conditions and applicable motor standard. The site classification determines whether the proposed protection type and certificate are relevant.

Which documents close the safety and fit decision?

Require the manufacturer to name one complete model code and provide its current certificate and scope, nameplate drawing, dimensional and terminal drawings, efficiency/test sheet, thermal and start-duty evidence, and instructions for glands, protection devices and maintenance. Series-level web text does not replace that pack.

What should be checked on arrival?

Compare received nameplate, Ex mark, serial/model, voltage connection, frame/shaft and certificate against the signed offer. Confirm preservation of flamepaths and permitted cable entry/accessories during installation. Do not assume a model-specific test for one production batch proves another series or configuration.

04 / IDENTITY VERSUS PRODUCT APPROVAL

Public listings support identity; site text does not prove every offered motor

Independent identity cross-check

A specialist explosion-protection industry association lists 江苏双云防爆电机有限公司 at the same Wuxi industrial-park address shown by the manufacturer. That historical membership entry helps match the company name and location; it is not a current approval or certification for YBK3, YBU, YBBP, YBS or a quoted serial number.

Manufacturer ranges remain series claims

The company's product pages repeat corporate capacity language and use unverified printed Ex strings. This profile uses the pages to distinguish application and stated family envelopes, but makes no independently certified output, capacity or hazardous-area suitability claim. A current certificate and model drawing must settle the final choice.

Published motor range

4 series
Winch motor

Winch motor

Ask about this series and the configuration that fits your application.

Company information

Company name
Jiangsu Shuangyun Explosion proof Motor Co., Ltd.
Chinese registered name
江苏双云防爆电机有限公司
Region
Jiangsu, China
Record updated
2026-10-07

Share with your team

Keep your sourcing team on the same page.

LinkedInFacebookXWhatsAppEmail