Application-specific motors
Horizontal cast-iron oil-pump motor
Zhejiang Baote Motor Co., Ltd- Phase
- Three-phase
- Frame Range
- 80–160L

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
The TOP catalogue shows two pump-end arrangements, and offers both arrangements in single-phase and three-phase versions. Phase count therefore does not identify the mounting. The same base-hole spacing can hide a different pump-end projection and overall length.
| Drawing 1: overall length 209 mm | The table gives reference dimension C = 54 mm and overall length L = 209 mm. This arrangement is listed twice, once for three-phase and once for single-phase construction. Use “drawing 1” with a marked pump-interface photograph or drawing in the enquiry. |
|---|---|
| Drawing 2: overall length 227 mm | The second arrangement gives C = 76 mm and L = 227 mm, again with both phase options. C changes by 22 mm while L changes by 18 mm; do not treat the difference as one simple extension dimension or infer an adaptor length from it. Request a dimensioned mating drawing for the actual assembly. |
| Shared base dimensions do not establish pump interchangeability | Both rows give A × B foot-hole spacing of 100 × 80 mm, shaft centre height H = 62 mm, body diameter AC = 129 mm and overall height HD = 127 mm. These values support a base and clearance check. They do not identify the pump register, bolt pattern or required drive engagement. |
Include the old motor nameplate, supply voltage and frequency, single- or three-phase requirement, and the chosen drawing number. For a single-phase replacement, obtain the specified capacitor and connection details if required by that version; the outline sheet does not provide them.
Send pump make/model, locating diameter, fixing-hole pattern, drive shape, engagement depth and direction of rotation, with the viewing direction marked. The TOP sheet has D and E columns but does not clearly dimension those features in the shown views. Do not machine an adaptor from an assumed interpretation.
The output column displays “1/4” beneath mixed kW and horsepower headings. It is not used here as a confirmed power rating. Supply the pump’s operating pressure and flow, start/stop sequence and required shaft speed so the accepted motor sheet can state the actual output, current and duty.
Measure the space for the terminal box and cable entry as well as the motor body. Compare the complete installed pump-and-motor length, not just the 209 or 227 mm motor outline, and retain access to mounting fasteners and maintenance points.
CATALOGUE OVERVIEW
Baote’s TOP lubrication-pump motor sheet shows two mounting arrangements for single- and three-phase variants. Both drawings use a 62 mm shaft-centre height; the listed overall lengths are 209 and 227 mm. The pump-side interface changes between the drawings, so a replacement needs the matching flange and shaft drawing. The power heading mixes horsepower wording with a kW label, and the fractional rating is therefore not converted into the output-power filter.
The power-column unit is ambiguous in the source sheet. Request a corrected electrical rating before selecting output power.
Model / series reference: TOP
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details