1TL8004 cast-iron induction motor

Manufacturer catalogue image · Series illustration

AC induction motors

1TL8004 cast-iron induction motor

Power
0.55–315 kW
Duty
S1
Cooling
IC411; IC416/IC410 options listed
Altitude
Up to 1000 m

Catalogue series · Exact configuration and availability confirmed by the manufacturer.

1TL8004 on a belt drive: check the shaft load as carefully as the kW

The July 2026 catalogue identifies 1TL8004 as the IE4 cast-iron range. For a belt-driven fan or machine, an efficient winding does not by itself settle the mechanical selection: pulley diameter, overhang and bearing option can determine whether the chosen frame is suitable.

A 7.5 kW example where a smaller pulley changes the answer

Start from an actual rated row

The four-pole 132M entry is 7.5 kW at 1475 rpm, with 48.6 Nm rated torque, 15.2 A listed current and 92.6% full-load efficiency. The table is for 380 V delta / 660 V star at 50 Hz. Its order stem is 1TL8004-1CB23-3, followed by configuration characters; it is not a complete order code.

Estimate belt force with stated assumptions

Using the catalogue approximation FQ = c × 20,000,000 × P / (n × D), take P = 7.5 kW, n = 1475 rpm and a V-belt pretension factor c = 2.5. A 100 mm pulley gives about 2542 N; a 160 mm pulley gives about 1589 N. These are illustrative calculations, not measured loads or an approved belt design. Obtain the belt maker’s actual pretension factor and include the real operating loads.

Compare at the actual pulley position

At the shaft-extension end, the four-pole 132 frame is listed for 1490 N in standard form or 2210 N with L22. The 100 mm example exceeds both. The 160 mm example exceeds the standard value but is below the L22 value under the table’s zero-axial-load assumption. That comparison is a screening step; the actual load position and combined loads still need approval.

Why moving the pulley outward reduces the available margin

Catalogue radial-force limits for four-pole 132S/132M, in newtons. x0 is at the shaft shoulder and xmax is at the end of the free shaft extension. The table assumes no axial force. Do not extrapolate beyond the shaft end.

Bearing arrangementAt shoulder x0At extension end xmaxOrder implication
Standard 1820 N 1490 N Check the installed pulley centreline, not only its diameter
L22 increased cantilever design 2690 N 2210 N Specify the option explicitly; it is not the default 132-frame bearing

Finish the specification around the drive, not just the efficiency label

Converter supply: the smaller frames have another voltage limit

The catalogue permits converter operation on standard insulation up to 380 V mains for frames 80–90, and up to 460 V for frames 100–355. Identify the actual frame, drive supply, speed range and load curve. A broad statement that the range accepts multiple voltages is not a substitute for this frame-dependent check.

Low-speed torque needs a cooling decision

The catalogue distinguishes self-ventilated and forced-ventilated load curves. Supply the minimum continuous speed and required torque so the cooling arrangement can be confirmed; an IC411 motor should not automatically be assigned full rated torque throughout an arbitrary speed range. For frames 250–355 on a converter, the catalogue also recommends considering insulated bearings.

Maintenance and order code must match the selected build

Frames 80–160 use the catalogue’s permanently lubricated bearing arrangement; frames 180–355 have regreasing provisions as standard. Specify the mounting code, terminal-box position, winding protection and bearing option with the electrical rating. For a belt drive, attach pulley diameter, belt type, pretension, pulley centreline distance from the shaft shoulder and any axial load.

CATALOGUE OVERVIEW

About this motor series

The July 2026 BEIDE catalogue identifies 1TL8004 as an IE4 cast-iron induction-motor range, covering 0.55–315 kW and frames 80–355. Standard specifications include S1 continuous duty, IC411 cooling, IP55 protection and class F insulation, for ambient temperatures from -15 to +40 °C and altitude up to 1000 m.

For a belt-driven replacement, select the winding and check the shaft loading separately. The catalogue provides frame- and pole-specific radial-force limits, an L22 bearing option for applicable frames, and separate converter-use conditions. Use the actual pulley size and overhang when matching the motor to the machine.

Model / series reference: 1TL8004

Published specifications

Specifications describe a series range; confirm which ratings apply together to the quoted model.

Power
0.55–315 kW
Duty
S1
Cooling
IC411; IC416/IC410 options listed
Altitude
Up to 1000 m
Enclosure
IP55
Insulation
Class F
Frame Sizes
80–355
Output Range
0.55–315 kW
Ambient Temperature
-15 to +40 °C
Voltage
Confirm supply
Speed
Model dependent