Submersible motors
6YC oil-filled submersible motor
Zhejiang Doyin Technology Co., Ltd.- Voltage
- 380–415 V three-phase; 50 Hz / 220–240 V single-phase
- Speed
- 2850 rpm

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
A 5YS order needs two matches: the electrical supply and the pump-end connection. The 50 Hz range includes single-phase models through 3 kW and three-phase models through 11 kW. The catalogue gives useful length and weight data, but its outline does not dimension the coupling or mounting interface.
These two exact rows share an approximately 2,850 rpm speed, 540 mm listed length and 22.3 kg weight. The M identifies the single-phase version; no M identifies three phase.
| Model | Supply at 50 Hz | Rated current | Power factor | Efficiency |
|---|---|---|---|---|
| 5YSM3000 | 220–240 V, single phase | 21.9 A | 0.93 | 67% |
| 5YS3000 | 380–415 V, three phase | 8.3 A | 0.79 | 73% |
Motor data only: add the pump-end length and mass separately when planning the complete installation.
| 5YS4000 — 4 kW | The 380–415 V three-phase row lists 10.5 A, 600 mm length and 27.1 kg. This is a longer and heavier motor than the 3 kW version even before attaching the pump. |
|---|---|
| 5YS7500 — 7.5 kW | The three-phase row lists 17.7 A, 770 mm length and 38.5 kg. Check the support and handling arrangement for the complete assembly rather than using the weight of the smaller motor. |
| 5YS11000 — 11 kW | The three-phase row lists 24.9 A, 880 mm length and 45.6 kg. The higher motor rating alone supplies no flow or head figure: the chosen pump must have its own hydraulic curve and shaft-power requirement. |
The product description specifies wells over 130 mm; do not round that down to a nominal 127 mm bore simply because the family is called 5-inch. Check the actual well clearance, cable space and cooling-water path around the assembled motor. The listed maximum fluid temperature is 35°C. The catalogue supplies no minimum cooling-flow velocity, so obtain the requirement for the proposed well or reservoir arrangement.
The published outline labels overall length L but does not dimension the shaft, mounting holes, register or axial-thrust capacity. Match those details to the existing pump drawing before ordering a replacement. Equal power, speed and overall length are insufficient evidence that two pump ends will couple correctly.
The installation diagram requires full submergence and vertical installation, shows at least 5 m clearance above the well bottom and states an 80 m maximum depth. This is installation guidance, not an 80 m pump-head guarantee. Include the dynamic water level, assembly setting depth and required discharge duty when requesting the motor-and-pump combination.
The family lists a start control box or digital auto-control box. Specify the single- or three-phase model, cable length and site supply; obtain the matched wiring and protection settings. Rated current is not the starting-current figure, and the family description does not give a capacitor value or universal starter connection.
The casing and bottom support are listed as AISI 304 stainless steel, while the top support is offered in cast iron or cast copper alloy. Confirm the supplied top-support and seal arrangement for the water chemistry. An oil-filled, rewindable construction and IP68 label do not establish corrosion suitability or potable-water certification.
Other voltages and 60 Hz are optional requests. The tabulated currents, efficiencies and approximately 2,850 rpm speed belong to the published 50 Hz rows. Ask for the selected frequency’s rating and pump curve instead of carrying the 50 Hz figures into a 60 Hz quotation.
CATALOGUE OVERVIEW
DOYIN lists the 5YS as a rewindable, oil-filled motor for deep-well pump installations. The manufacturer specifies wells over 130 mm in diameter, 2,850 rpm at 50 Hz, class F insulation and IP68 protection. Its published applications include well or reservoir water supply and irrigation.
The motor is a drive component; the pump hydraulic section must be selected separately. Confirm the exact motor rating, shaft and coupling dimensions, starting arrangement, cable length and cooling conditions against your pump. The published maximum fluid temperature is 35°C. Request the selected model datasheet before ordering.
Model / series reference: 5YS
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details