AC induction motors
YY capacitor-run single-phase induction motor
Zhejiang Hongda Group Dafeng Electronics Co., Ltd.- Power
- 0.025–2.2 kW
- Voltage
- 110 / 220 V

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
The GOST single-phase catalogue separates permanent-capacitor AIRE motors from two-capacitor AIRE2 motors. Frame 71B illustrates the replacement trap: both groups share key mounting dimensions, but the AIRE2 outline is longer. Check the starting load before deciding that a matching shaft is enough.
Dimensions are in millimetres. These rows share shaft diameter D = 19, extension E = 40, key width F = 6, centre height 71 and foot spacing A × B = 112 × 90. The overall length still changes with circuit family and pole count.
| Family | Circuit | Poles | Overall L | Difference from matching AIRE |
|---|---|---|---|---|
| AIRE-71B | Permanent capacitor | 2 | 262 | Reference |
| AIRE2-71B | Two capacitors | 2 | 306 | 44 mm longer |
| AIRE-71B | Permanent capacitor | 4 | 278 | Reference |
| AIRE2-71B | Two capacitors | 4 | 322 | 44 mm longer |
The AIRE-71B2 row lists 0.75 kW, 220 V, 2780 rpm and 5.2 A. Its starting-current ratio is 4 and starting-torque ratio is 0.4. The current ratio implies about 20.8 A at start; it is not a protection setting. The low torque ratio is a reason to check breakaway load, rather than assuming the motor will start a loaded machine because its running kW matches.
The two-capacitor family has its own starting arrangement and outline. Ask for the selected AIRE2 winding’s performance sheet, start/run capacitor values and voltage ratings, and the starting-device specification. The permanent-capacitor table is not evidence of the two-capacitor version’s torque or current.
The 71B dimensional rows give flange P = 200, pitch circle M = 165, register N = 130 and hole S = 12. Mark the required B3 foot-only or B35 foot-and-flange arrangement. Compare the full interface drawing and tolerances with the driven unit; a GOST frame name alone does not establish interchangeability with an IEC motor.
Send the existing nameplate, capacitor labels, mounting photographs, available axial clearance and supply conditions. Explain whether the machine starts unloaded, how often it restarts and whether reversal is required. Obtain the actual winding connection diagram; do not move terminal links by analogy with a three-phase motor or another capacitor configuration.
CATALOGUE OVERVIEW
Dafeng’s GOST single-phase range distinguishes AIRE permanent-capacitor motors from AIRE2 two-capacitor versions. The dimensional sheet includes B3 foot-mounted and B35 foot-and-flange arrangements. In the permanent-capacitor group, AIRE-56B is shown with a 56 mm centre height, an 11 mm shaft diameter and a 23 mm shaft extension; overall length is 206 mm.
The mounting suffix and starting circuit both matter in a replacement. The AIRE-71B two-pole and four-pole entries share a 19 mm shaft but have different overall lengths, 262 and 278 mm. Specify the capacitor arrangement, pole count and drawing dimensions before comparing an AIRE motor with a similarly numbered IEC frame; the source does not establish universal interchangeability.
Model / series reference: AIRE / AIRE2
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.