AC induction motors
IE3 aluminium-housing three-phase induction motor
Deli Motor Co., Ltd.- Power
- 0.75–18.5 kW
- Frequency
- 50 Hz

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
For a 3 kW machine, this catalogue offers two-, four- and six-pole entries with substantially different rated speeds, torques and frame designations. The 3000, 1500 and 1000 rpm headings are synchronous speeds; they are not the loaded speeds the selected motor will deliver.
Values are from the 50 Hz IE2 table. Use the complete model designation when requesting the installation drawing; the shared 3 kW output does not establish mechanical interchangeability.
| Model | Rated speed | Rated torque | Listed efficiency | Power factor |
|---|---|---|---|---|
| IE2-100L-2 | 2880 rpm | 9.95 N·m | 86.7% | 0.87 |
| IE2-100L2-4 | 1450 rpm | 19.7 N·m | 87.4% | 0.82 |
| IE2-132S-6 | 970 rpm | 29.5 N·m | 84.9% | 0.74 |
The six-pole IE2-132S-6 row is rated at 970 rpm, 3% below its 1000 rpm synchronous-speed heading. For a process that must run near a particular speed, state the allowable speed tolerance and load range. A single rated point does not describe speed over the whole operating cycle.
At the same 3 kW rating, the two-pole entry turns about 2.97 times as fast as the six-pole entry. Reusing the same pulley or gearbox ratio would therefore change the driven speed. Send the transmission ratio and required machine speed with the enquiry, rather than specifying only “3 kW IE2”.
The table moves from 100L or 100L2 designations to 132S for the six-pole choice. Obtain that model’s shaft, foot or flange dimensions and check alignment, coupling and space. Do not use the separately published YEJ2 brake-motor outline as a substitute IE2 drawing.
| An explicit full-load calculation | At 3 kW shaft output, dividing output by the listed efficiency gives approximately 3.46 kW input for IE2-100L-2, 3.43 kW for IE2-100L2-4 and 3.53 kW for IE2-132S-6. These are calculations at the catalogue rated condition, not measured energy use or an annual saving prediction. |
|---|---|
| Do not let a small efficiency difference choose the wrong drive | The four-pole row has the highest listed efficiency among these three entries, but it does not deliver the six-pole row’s speed or torque. Compare complete drives at the same required machine duty, including transmission losses and actual loading. Request part-load information if the machine seldom runs near rated output. |
| Confirm the electrical sheet before sizing equipment | The published IE2 image lists current but does not identify its voltage alongside that column, and its far-right ratio heading is repeated ambiguously. Request a voltage-specific current and starting-performance sheet for the chosen model. This page does not relabel that ambiguous ratio as starting current or use it for protection selection. |
CATALOGUE OVERVIEW
Deli’s IE2 performance sheet separates 50 Hz two-, four- and six-pole motors. The two- and four-pole tables cover 0.75–7.5 kW; the six-pole table covers 0.75–5.5 kW. For example, IE2-90S-2 is listed at 1.5 kW, 2890 rpm and 4.95 Nm. These are model-row values, while 3000, 1500 and 1000 rpm are synchronous-speed headings. Use the selected row and matching mounting drawing for replacement work.
Model / series reference: IE2
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details