AC induction motors
IE2 aluminium-housing three-phase induction motor
Deli Motor Co., Ltd.- Power
- 0.75–7.5 kW
- Frequency
- 50 Hz

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
Deli’s IE3 frames 100L and 112M share a 28 × 60 mm shaft and the same listed flange interfaces. However, the B14 and B5 options have different registers, bolt circles and fixing holes. A matching coupling bore therefore answers only one part of the replacement question.
Dimensions are in millimetres unless identified as a thread. These values come from the IE3 outline sheet, not the YEJ2 brake-motor drawing. The B14 drawing uses threaded fixing holes; the B5 drawing uses through holes.
| Interface feature | B14 | B5 |
|---|---|---|
| Pitch circle M | 130 | 215 |
| Register diameter N | 110 | 180 |
| Outer flange diameter P | 160 | 250 |
| Fixing hole S | M8 thread | 15 mm through hole |
| Register projection T | 3.5 | 4.0 |
| Shaft diameter D / extension E | 28 / 60 | 28 / 60 |
| Shaft key width F | 8 | 8 |
| Foot alignment and body clearance still change | The IE3 outline gives centre heights of 100 and 112 mm, transverse foot centres A of 160 and 190 mm, and overall lengths of 392 and 406 mm for 100L and 112M. Their axial foot spacing B is 140 mm. Where feet are part of the selected arrangement, check the baseplate and centreline instead of relying on the common flange dimensions. |
|---|---|
| The full model suffix selects the rating | At 50 Hz, IE3-100L1-4 is listed at 2.2 kW, 1435 rpm and 14.6 N·m; IE3-100L2-4 is 3 kW, 1435 rpm and 20 N·m. The 112M four-pole entry is 4 kW, 1440 rpm and 26.5 N·m. A request for “100L B14” alone omits the winding/rating distinction between the first two entries. |
| Check the fastener engagement, not just the thread name | For B14, request usable thread depth and the mating component’s thickness before choosing bolt length. The catalogue specifies M8 but does not provide engagement depth. For B5, confirm the mating through-hole pattern, register fit and access for the specified fasteners. Send the driven-unit drawing with the selected mounting code. |
For the 2.2 kW 100L1-4, 3 kW 100L2-4 and 4 kW 112M-4 examples, the 380 V current column lists 4.93, 6.66 and 8.56 A respectively. State the actual supply voltage and frequency in the RFQ and obtain the matching nameplate and connection diagram.
The current headers read 380, 450 and 415; the middle value is not silently changed to 400 here. The part-load efficiency heading also has a Chinese 50% label paired with English text saying 75%. Request a corrected model sheet before using those columns in an energy or current calculation. A catalogue efficiency label alone does not establish approval under the destination’s current requirements.
CATALOGUE OVERVIEW
Deli’s IE3 table lists 0.75–18.5 kW two-pole motors, 0.75–15 kW four-pole motors and 0.75–11 kW six-pole motors at 50 Hz. The IE3-90S-2 row gives 1.5 kW, 2895 rpm and 4.95 Nm. Efficiency and current must be compared at the same rating and load, rather than taking one value for the whole family.
The image labels its current columns 380, 450 and 415. Confirm the intended middle voltage with Deli before using its current figures.
Model / series reference: IE3
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details