AC induction motors
IE2 aluminium-housing three-phase induction motor
Deli Motor Co., Ltd.- Power
- 0.75–7.5 kW
- Frequency
- 50 Hz

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
Deli’s attached four-pole table gives separate motor current, inverter capacity and fan supply data. For the 3 kW YVF100L2-4 example, 6.8 A, 6 kVA and 52 W refer to different parts of the installation. Keeping those quantities separate helps define a useful low-speed drive quotation.
The product text calls this family YVF2; the attached rows use YVF model codes. Retain the exact quoted order code. The table does not establish identical ratings for the optional YVF2EJ brake derivative.
| Catalogue item | YVF100L2-4 | YVF112M-4 |
|---|---|---|
| Motor nominal output | 3 kW | 4 kW |
| Listed motor current | 6.8 A | 9.3 A |
| Listed nominal torque | 19 N·m | 25.4 N·m |
| Suggested inverter capacity | 6 kVA | 10 kVA |
| Separate fan supply | 380 V, 50 Hz | 380 V, 50 Hz |
| Fan power | 52 W | 60 W |
| Fan speed | 2800 rpm | 2800 rpm |
The fan rows specify fixed 380 V, 50 Hz supply while the motor is intended for a variable-frequency drive. Ask for the approved separate fan connection and control diagram, including the cooling sequence and response to loss of airflow. Do not treat the fan wattage as motor output or assume that the fan can simply follow the motor’s variable frequency.
The attached table labels 5–50 Hz as the constant-torque range and separately lists a 50–100 Hz band. Obtain the selected motor-and-drive load curve before using the higher band, and do not extrapolate the 5 Hz lower bound to continuous zero-speed torque. Give the supplier the minimum operating frequency, load torque and duration of each operating stage.
The 6 and 10 kVA figures are catalogue inverter-capacity entries, not motor kW or output amperes. Check the proposed drive’s output-current rating, overload duration, control mode and supply against the selected motor nameplate. The page’s general vector-control wording does not establish compatibility with every drive or control setting.
| 100L2 and 112M do not share the same body envelope | The attached B3 drawing lists frame 100L at 465 mm overall length and 100 mm centre height, with foot centres A × B = 160 × 140 mm. Frame 112M is 480 mm long and 112 mm high, with A × B = 190 × 140 mm. Both list a 28 mm shaft and 60 mm extension. Check the fan-end space and final order drawing rather than reusing a standard motor outline. |
|---|---|
| Brake and larger-frame variants need their own confirmation | YVF2EJ is offered on request, but this page does not give its braking torque, coil supply or finished length. The attached sheets also contain conflicting values for some other entries, including the 132S power in the auxiliary table and the 132-frame B35 shaft diameter. Do not resolve those by averaging or copying the more convenient value; request the selected variant’s corrected sheet. |
CATALOGUE OVERVIEW
Deli’s square aluminium YVF2 range covers eight frame sizes from 56 to 132, with two-, four-, six- and eight-pole variants. An independent cooling system supports low-speed operation with a frequency converter. The manufacturer also offers a YVF2EJ electromagnetic-brake derivative on request. Specify the inverter speed range and whether the brake derivative is required before comparing this range with a standard Y2 motor.
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details