The YEXA installation sheet separates two-pole shafts from the slower-pole shafts in frames 315 and 355. Its thermal notes also make exceptions for these large frames. Check both details before retaining an existing coupling or specifying a winding-temperature alarm.
Selected dimensions from the installation sheet displayed for YEXA, in millimetres. D is drive-end shaft diameter, E is shaft extension and F is key width. The 4–10-pole grouping describes the drawing rows, not a guarantee that every power/pole combination is offered.
| Frame group | Poles in drawing | D shaft | E extension | F key width |
|---|---|---|---|---|
| 315S / 315M / 315L | 2 | 65 | 140 | 18 |
| 315S / 315M / 315L | 4–10 | 80 | 170 | 22 |
| 355M / 355L | 2 | 75 | 140 | 20 |
| 355M / 355L | 4–10 | 95 | 170 | 25 |
The YEXA performance sheet specifies class F insulation, described as 155 °C, and an 80 K temperature-rise assessment under rated output and direct supply. It separately permits 105 K for frame 315 two- and four-pole motors and for frame 355 motors. Temperature rise is an increase above the reference condition; it is not the same quantity as the insulation-class temperature.
The sheet offers PTC or Pt100 winding protection and additional winding-temperature measurement; bearing-temperature measurement is an option on frames 160 and above. Identify the machine’s required alarm/trip functions and measurement interface, then obtain the approved settings for the supplied motor. Do not enter 80 or 105 as a temperature-alarm setting simply because that number appears in the catalogue.
Standard construction is IC411 with a non-drive-end fan. The sheet also describes cooling by the driven fan’s airflow when the motor fan is omitted and sufficient cooling airflow is available. That is an application-dependent arrangement: send the airflow and duty conditions for assessment before requesting a fanless version, particularly where the driven fan may run slowly or stop.
Send the full frame and pole designation, mounting form, coupling bore/key details and shaft engagement length. For the 315 and 355 rows above, keeping the centre height while changing poles can change both shaft diameter and extension. Confirm the toleranced drawing before modifying a hub or coupling.
The YEXA page directs readers to YE3 electrical parameters and displays tables bearing YE3 model names. Use those as the manufacturer’s reference, then obtain the offered YEXA model’s rated current, torque, starting performance and efficiency sheet. The statement that starting performance is optimised is not a numerical torque curve.
The performance sheet lists grease nipples as standard for two-pole frames 200 and above and for frames 315–355; frames 132 and above can be ordered with them. Confirm the bearing and lubrication arrangement with the selected build, and leave physical access for maintenance in the machine layout.
CATALOGUE OVERVIEW
Chuangxin describes YEXA as an enclosed, self-fan-cooled, single-speed three-phase induction motor for continuous duty. Listed applications include fans, pumps and machine tools. The manufacturer states IE3 efficiency to IEC 60034-30 and grade 3 under GB 18613-2020. Confirm the selected output and pole count against its electrical table before comparing efficiency at the required load.
Model / series reference: YEXA
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details