DL-PS IC410 permanent-magnet synchronous motor

Manufacturer catalogue image · Series illustration

Permanent magnet motors

DL-PS IC410 permanent-magnet synchronous motor

Power
0.25–18.5 kW
Voltage
220 / 380 V
Duty
S3 40%
Cooling
IC410

Catalogue series · Exact configuration and availability confirmed by the manufacturer.

DL-PS IC410: the inverter frequency is not the shaft-speed specification

Dongling’s self-cooled DL-PS catalogue contains both 16-pole and 8-pole motor groups. That distinction matters when replacing or commissioning the drive: 100 Hz corresponds to 750 rpm in one group and 1,500 rpm in the other. Order and configure the complete model, including its speed suffix, rather than selecting a motor from inverter frequency alone.

Read pole count together with the speed suffix

These are distinct catalogue rating groups, all shown with S3 40% duty. The rows do not establish that every winding can operate continuously across the entire 375–3,000 rpm span.

Rated-speed groupListed motor frequencyPole count
375 rpm 50 Hz 16
500 rpm 66.7 Hz 16
600 rpm 80 Hz 16
750 rpm 100 Hz 16
1,000 rpm 66.7 Hz 8
1,500 rpm 100 Hz 8
2,250 rpm 150 Hz 8
3,000 rpm 200 Hz 8

Use one complete row for the motor data entered into the drive

A concrete 1,500 rpm entry

DL90-PS10S-1.5K is listed at 1.5 kW, 100 Hz and 8 poles, with 5.6 A at 220 V or 3.25 A at 380 V. The source gives 88.2% efficiency and 9.8 kg for this entry. These values identify that row; they are not a family-wide efficiency or current rating.

The 750 rpm entry is a different selection

DL90-PS10L-750 is also listed at 1.5 kW and 100 Hz, but uses 16 poles and a longer 90L frame. Its listed current is 5.9 A at 220 V or 3.42 A at 380 V, efficiency 84%, and weight 13.2 kg. Substituting the 1,500 rpm row’s parameters would misidentify both the pole count and the motor configuration.

Keep sensorless control and the duty rating in the specification

The catalogue calls for a position-sensorless PM synchronous motor driver with vector control. It shows star and delta terminal-link arrangements, but the diagram alone does not assign a voltage to each connection for the delivered winding. Obtain the nameplate connection and approved motor parameters. The published IC410 self-cooling and S3 40% duty also require the actual run/rest cycle to be checked; this is not an S1 continuous-output claim.

Frame 90: distinguish the short body and the two flange choices

90S versus 90LThe dimension table lists 228 mm overall L for 90S and 253 mm for 90L. Both have a 24 mm shaft and 50 mm shaft extension, but the foot-hole B pitch is 100 mm on 90S and 125 mm on 90L. A coupling that fits does not mean the base holes or installation length will fit.
IMB14 / IMB34 small flangeFor frame 90 the table gives a 115 mm bolt circle, 95 mm register, 140 mm outside diameter and M8 fixing threads. Use this group only for the small-flange arrangement shown in the catalogue.
IMB5 / IMB35 large flangeThe frame-90 large-flange group instead lists a 165 mm bolt circle, 130 mm register, 200 mm outside diameter and 11 mm holes. Supply the mounting code and measured flange interface in the inquiry; “frame 90 flange motor” is not enough to distinguish these two arrangements.

CATALOGUE OVERVIEW

About this motor series

Dongling’s DL-PSIC410 permanent-magnet motor sheets list eight rated-speed groups from 375 to 3000 rpm. The combined output range is 0.25–18.5 kW, with different limits in each group: the 375 rpm table reaches 5.5 kW, while the 2250 and 3000 rpm tables reach 18.5 kW. The specified duty is S3 40%. These speed groups are separate ratings with different electrical frequencies, not a constant-torque operating curve for one motor.

Model / series reference: DL-PS

Published specifications

Specifications describe a series range; confirm which ratings apply together to the quoted model.

Power
0.25–18.5 kW
Voltage
220 / 380 V
Duty
S3 40%
Cooling
IC410
Product Type
DL-PS IC410 permanent-magnet synchronous motor
Catalogue Scope
Manufacturer model or series
375 Rpm Frequency
50 Hz
3000 Rpm Frequency
200 Hz
Rated Speed Groups
375 / 500 / 600 / 750 / 1000 / 1500 / 2250 / 3000 rpm
Combined Tabulated Output
0.25–18.5 kW
Speed
Model dependent
Manufacturer
Dongling Motor

Confirm mounting and shaft dimensions against the drawing for the quoted configuration.