Z medium-size DC motor

Manufacturer catalogue image · Series illustration

DC motors

Z medium-size DC motor

Voltage
220 / 330 / 440 / 550 / 660 V
Duty
S1
Insulation
Class F
Field Supply
220 V series / 110 V parallel

Catalogue series · Exact configuration and availability confirmed by the manufacturer.

Read the Z motor overload class before comparing its kilowatt rating

In Haze’s medium-size Z range, A and B identify different motor duty classes. The A-class short-time table is expressed as percentages of rated current, while the B-class description specifies power and time conditions. Treating all of these numbers as interchangeable torque margins would lead to the wrong drive selection.

A-class current limits and B-class power allowances are different specifications

Class A: a one-minute current envelopeThe manufacturer separates occasional and regularly recurring short-time overload, each tabulated as a percentage of rated current. Values depend on operating speed and on whether the motor’s base speed crosses a frame-specific threshold. Regular overload must be followed by lighter running so the cycle’s RMS load stays within the continuous rating. This is not permission to hold the tabulated current continuously.
Class B: a differently rated motorHaze says a B-class motor has lower rated output than an A-class motor of the same centre height and axial foot spacing. Its description permits 115% rated power continuously under the specified voltage/speed conditions, with higher temperature rise, and 125% for two hours after rated-load running. These statements belong to the B rating. They cannot be added to an A motor’s nameplate or stacked with the A-class current table.

How the high-base-speed rule changes a frame-400 reading

The threshold table gives 900 rpm for a 400 mm centre height. For an A-class motor at or above that base speed, the bracketed values apply where shown. The resulting one-minute current limits are below. These are conditional catalogue limits, not a claim that a selected motor is mechanically approved for three times base speed.

Operating speed / base speedOccasional current / rated currentRecurring current / rated current
100% 180% 160%
200% 180% 160%
300% and above 160% 140%

Send a load-cycle brief that a drive engineer can actually assess

Identify the class and retain the original output requirement

The illustrated model key defines the final A or B as the motor class, and the preceding number as an ordinal axial foot-spacing code. Haze describes increasing the requested B-class power by about 25% only to shortlist a size from an A-class table; the required B output stays unchanged. That preliminary sizing method is not a 25% output upgrade. Obtain the final B-class rating and drawing rather than relabelling an A quotation.

State current, speed, duration and recovery separately

Provide the base speed, operating-speed range, load/current trace, each overload duration and the lighter-running interval. For the frame-400 example, a base speed below 900 rpm uses different unbracketed entries in the source table; do not reuse the table above without checking the threshold. A headline “200% overload” omits both the time limit and the operating point.

Verify the rectifier at the specified operating point

The source requires at least six rectifier pulses and a peak ripple factor no greater than 10% at rated base speed, voltage and load current. A matching DC voltage alone does not establish converter compatibility. Have the drive supplier confirm the ripple definition, measurement point and the proposed converter’s result at that condition, alongside the armature and separate field ratings.

Keep exceptional overload separate from normal production

For B-class motors, the stated occasional 2.5-times overload at base speed is limited to 15 seconds and explicitly requires agreement with the manufacturer. It is not a standard repetitive cycle. Include any emergency duty in the specification, and obtain the unit-specific thermal, commutation and protection limits rather than deriving trip settings from this summary.

CATALOGUE OVERVIEW

About this motor series

Haze’s medium-size Z DC family covers centre heights from 315 to 560 mm. The standard armature-voltage list is 220, 330, 440, 550 and 660 V. Separate excitation uses two field groups: series connection is listed at 220 V and parallel connection at 110 V. Rated duty is S1 with class F insulation.

The source distinguishes A- and B-duty variants, so equal frame sizes need not have equal continuous output or overload capability. IP23/IP44 enclosures and IC06, IC17, IC37 or ICW37A86 cooling are selected combinations. Provide the load cycle, rectifier supply and cooling services before requesting a model; the converter pulse count and ripple are part of compatibility.

Model / series reference: Z

Published specifications

Specifications describe a series range; confirm which ratings apply together to the quoted model.

Voltage
220 / 330 / 440 / 550 / 660 V
Duty
S1
Insulation
Class F
Field Supply
220 V series / 110 V parallel
Product Type
Z medium-size DC motor
Centre Height
315–560 mm
Catalogue Scope
Manufacturer model or series
Cooling Options
IC06 / IC17 / IC37 / ICW37A86
Enclosure Options
IP23 / IP44
Armature Supply Options
220 / 330 / 440 / 550 / 660 V
Power
Confirm configuration
Speed
Model dependent
Manufacturer
Haze Motor

Confirm mounting and shaft dimensions against the drawing for the quoted configuration.

Share with your team

Keep your sourcing team on the same page.

LinkedInFacebookXWhatsAppEmail