ZSN4 DC motor

Manufacturer catalogue image · Series illustration

DC motors

ZSN4 DC motor

Power
40–355 kW
Duty
S1
Insulation
Class F
Application
Cement rotary-kiln main drive

Catalogue series · Exact configuration and availability confirmed by the manufacturer.

Plan the ZSN4 kiln replacement around the air system and foundation

A replacement kiln motor can match kilowatts and armature voltage yet fail to fit the foundation or receive enough cooling air. Haze’s ZSN4 documentation gives frame-specific ventilation requirements and an explicit exception for the axial foot-hole dimension. Resolve these interfaces before treating the motor as an interchangeable Z4-derived drive.

Size the ventilation path for the selected frame

For duct-ventilated ZSN4 motors, Haze specifies the following airflow and static-pressure pairs. The inlet is on the non-commutator end cover. Compare these duties with the proposed blower and installed duct system, not merely a blower’s free-air flow figure.

Motor frameAirflow (m³/h)Static pressure (Pa)
ZSN4-225 2,880 1,400
ZSN4-250 3,000 1,400
ZSN4-280 4,000 1,600
ZSN4-315 4,680 1,600
ZSN4-355 5,200 1,600

Three interfaces to close before the kiln shutdown

Air inlet, outlet and enclosure must be ordered together

The detailed configuration table pairs IC17 single-inlet duct cooling with IP23S, and IC37 inlet-and-outlet duct cooling with IP44. The introductory IP21S label is not a blanket rating for these two arrangements. Specify the actual air route, dust exposure, available blower duty and filtration arrangement. The stated inlet-air limit is 40°C at an installation altitude up to 1,000 m; ambient temperature beside the kiln does not establish the temperature delivered through the duct.

Measure the axial foot-hole spacing B

Haze excludes dimension B from its claim that external mounting dimensions follow IEC72. That exception matters when reusing an existing foundation: the motor can share a shaft-height family and still miss the anchor-bolt pattern. Provide the measured foundation drawing, shaft and coupling dimensions, and the non-drive-end clearance for any speed-feedback device. The documented arrangement is horizontal foot mounting; single or double shaft extensions and terminal-box changes need to be specified.

Check both DC supplies and the starting requirement

The detailed standard arrangement is a 440 V armature and a separate 180 V field supply, with other voltages by agreement. Record the installed drive’s armature and field ratings separately. Haze states starting torque can reach 2.5 times rated torque, but publishes no allowable duration here; do not use that statement as a continuous overload rating or a drive current setting. Its ZSN4-225 description specifically says a series field is fitted without a compensating winding, so that variant needs an explicit match to the proposed converter and load cycle.

Separate the model suffix B from foundation dimension B

In the illustrated ZSN4-280-091B model key, 280 is the centre height, 09 is the armature-core length code, 1 denotes the short end cover and the final B denotes a compensating winding. The key gives 2 for a long end cover. This final B is unrelated to the axial mounting dimension B: neither the suffix nor the family name verifies the anchor spacing. Preserve the full ordered suffix when comparing quotations and spare-machine drawings.

Make the quotation cover the equipment needed for commissioning

Motor and auxiliary energy on the same boundary

The manufacturer says its listed motor efficiency includes field losses but excludes ventilation power. A plant energy comparison should therefore include the actual blower input separately. No rated efficiency number or annual saving is inferred from the 40–355 kW family range.

List feedback, thermal protection and service spares

A non-drive-end tachogenerator or other speed device and embedded thermal elements are options, not confirmed standard equipment. Haze’s ordering notes also exclude accessories other than the shaft key unless agreed. Name the required feedback type, protection elements, spare brushes and brush holders, and identify which supplier provides the blower and ducts.

Approve a unit-specific acceptance sheet

Use one sheet for the ordered motor’s power, speed, armature and field ratings, cooling/enclosure combination, dimension B and shaft drawing. Add the agreed starting duty and checks of the installed air supply and feedback signals. Historical standard references on the catalogue page are not a current certificate for the offered unit.

CATALOGUE OVERVIEW

About this motor series

Haze’s ZSN4 is a DC main-drive family for cement rotary kilns. The introductory rating range is 40–355 kW, with listed base-speed options of 750, 1000 and 1500 rpm. The detailed specification gives a standard 440 V armature and 180 V field circuit, F-class insulation and S1 duty.

Ventilation is a separate selection requirement in a dusty kiln installation. The source pairs IC17 ducted inlet cooling with IP23S and IC37 inlet/outlet ducting with IP44. For example, its ZSN4-225 ventilation requirement is 2880 m³/h at 1400 Pa. Select the complete cooling/enclosure option; the headline IP21S entry should not be applied to every version.

Model / series reference: ZSN4

Published specifications

Specifications describe a series range; confirm which ratings apply together to the quoted model.

Power
40–355 kW
Duty
S1
Insulation
Class F
Application
Cement rotary-kiln main drive
Product Type
ZSN4 DC motor
Catalogue Scope
Manufacturer model or series
Base-speed Options
750 / 1000 / 1500 rpm
Standard Field Supply
180 V
Ducted Cooling Options
IC17/IP23S; IC37/IP44
Standard Armature Supply
440 V
Voltage
Confirm supply
Speed
Model dependent
Manufacturer
Haze Motor

Confirm mounting and shaft dimensions against the drawing for the quoted configuration.

Share with your team

Keep your sourcing team on the same page.

LinkedInFacebookXWhatsAppEmail