Brushless DC motors
NXK83A brushless bypass blower motor
Ningbo Newthink Motor Co., Ltd- Net Weight
- 2.2 kg
- Product Type
- NXK83A brushless bypass blower motor

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
NXK73C1200Z005 is listed in both 120 V and 230 V versions, but their pressure–flow curves separate substantially once flow increases. Match the supply-specific curve, then check the side outlet and five-position harness against the space and controller in your machine.
At approximately 210 m³/h, the 230 V NXK73C1200Z005 curve reads about 6.5 kPa, while the 120 V curve reads about 5 kPa. These are approximate graph readings, not guaranteed operating points. A design needing around 6 kPa at that flow therefore cannot treat the two versions as interchangeable merely because both list a 10 kPa maximum vacuum.
The table lists NXK73C1200Z005 at 850 W maximum input and 276 m³/h maximum airflow for 120 V, versus 1,100 W and 300 m³/h for 230 V. Both rows list 15,000 rpm maximum speed and 2.55 kg mass. Keep the voltage and model suffix together in the inquiry; neither the common speed limit nor the common mass makes their curves identical.
NXK73-0500-FZ01 is listed at 230 V, 550 W maximum input, 250 m³/h maximum airflow, 8 kPa maximum vacuum and 13,500 rpm. Its curve is below both C1200Z005 versions through much of the range. Use its own curve for a low-resistance duty instead of applying the 300 m³/h figure from the larger variant.
The published lines stop above zero pressure; do not extend them to invent a free-air endpoint or extrapolate a blocked-flow duty allowance. Provide the required flow together with the pressure drop of the installed air path and filter. The catalogue watts are maximum input, not guaranteed air power or continuous shaft output.
| The side outlet determines the duct layout | The drawing shows a 192.2 mm overall front-view width, 188 mm height and 147.2 ±0.5 mm axial dimension, with a 144.4 mm motor-body diameter. The outlet’s E-view is a shaped flange with its own 50 mm dimension and 4 mm hole callout. Use that section to design the mating duct; treating the blower as only a round 7.3-inch package omits the outlet projection. |
|---|---|
| The harness contains power and a low-level command | The five-position drawing labels 1 as blue DC−, 2 as red DC+ for the 0–10 V speed command, 3 as yellow/green ETH, 4 as black AC N and 5 as white AC L. Confirm the connector orientation and selected variant’s wiring before assembly. The 0–10 V pair is the command interface, not the main supply. Although PWM is advertised too, this drawing does not establish its connection or frequency specification. |
| Protect the installed assembly | The product is listed IP20, class F and fitted with sealed ball bearings. Select enclosure protection and ventilation for the real environment; those bearing seals do not make the complete blower suitable for water spray. Keep cable routing and the airflow openings clear when checking the package, and obtain the chosen variant’s thermal and duty limits for sustained suction. |
CATALOGUE OVERVIEW
NEWTHINK’s NXK73 bypass blower table lists configurations at 550, 850 and 1100 W maximum input. The 230 V, 550 W row specifies 250 m³/h maximum airflow and 8 kPa maximum vacuum; the 230 V, 1100 W row specifies 300 m³/h and 10 kPa. These are blower-system input figures rather than shaft-output ratings for a bare motor.
Published watts are maximum electrical input, not rated shaft output; they are not inserted into the output-power filter.
Model / series reference: NXK73
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details