Brushless DC motors
NXK57B brushless bypass blower motor
Ningbo Newthink Motor Co., Ltd- Frequency
- 50 / 60 Hz
- Net Weight
- 2.50 kg

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
The NXK83A page describes a blower for heating equipment and mentions an application heat-output ceiling of 160 kW. Its own electrical table lists 300 W maximum input. Select it from the required air duty and the appliance controls, then match the separate mains, speed-command and tachometer interfaces.
The manufacturer presents the range for combustion-heating applications with heat output up to 160 kW. That does not establish the fuel, burner pressure drop, air–fuel ratio, emissions performance or approval of a particular appliance. The blower’s listed maximum electrical input is 300 W for both voltage variants. A heating-system selection needs its own air requirement and validated operating range.
NXK83-0300-FZ01 is listed at 230 V with maxima of 300 m³/h, 4.7 kPa and 10,300 rpm. FZ02 is listed at 120 V with 288 m³/h, 4.8 kPa and 10,040 rpm. FZ02 has the slightly higher low-flow pressure, but the plotted curves cross near 140 m³/h; at greater flow the FZ01 line is higher. The 4.8 kPa headline therefore does not identify a better blower at every duty point.
Use the required combustion-air flow together with the pressure drop of the appliance air path. Check the selected voltage-specific curve at that pair of values and at the required modulation range. The curve does not establish ignition sequencing, flame supervision or appliance safety interlocks; those remain part of the appliance design and validation.
| Air inlet, side outlet and mounting | The outline gives a 210.3 mm height, 188.7 mm front-view width and maximum 142 mm depth. The inlet view includes separate 70 and 77 mm diameter callouts, a 100 mm pitch-circle callout and distinct M6 and M4 mounting features. The outlet Y-view has its own 50.2 mm geometry and 5.6 mm fixing callouts. Use the actual section and fastener pattern rather than assuming that “8.3 inch” defines a round duct connection. |
|---|---|
| Mains connector versus command connector | The drawing separates L, N and PE power terminals from a five-position signal connector labelled (+), tach out, 0–10 V, PWM and (−). This allows the wiring specification to distinguish commanded speed from the tachometer output. It does not state the tachometer pulse count, signal voltage or PWM frequency, so obtain those interface values before configuring the machine controller. |
| Housing and environmental enclosure | The range is described with a die-cast aluminium housing and metal impeller, IP20 protection and class F insulation. Those construction details do not establish wet-air, condensing-flue-gas or explosive-atmosphere suitability. Define the air composition, temperature and condensation exposure for the selected heating appliance, and keep the motor ventilation and electrical enclosure appropriate to that service. |
CATALOGUE OVERVIEW
NEWTHINK’s NXK83A bypass blower table lists a 230 V, 50/60 Hz variant at 300 W maximum input, 300 m³/h maximum airflow and 4.7 kPa maximum vacuum. A 120 V variant is separately rated at 288 m³/h and 4.8 kPa. Maximum airflow and vacuum are different endpoints of the performance curve, not a simultaneous operating point.
Published watts are maximum electrical input, not rated shaft output; they are not inserted into the output-power filter.
Model / series reference: NXK83A
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details