Permanent magnet motors
Permanent magnet synchronous motor
Shanghai Top Motor Co.,Ltd.- Motor Type
- Permanent-magnet synchronous
- Catalogue Series
- EC / ECI

Manufacturer catalogue image · Series illustration

Catalogue series · Exact configuration and availability confirmed by the manufacturer.
A 22 kW TYCP can mean 70 Nm at 3,000 rpm or about 210 Nm at 1,000 rpm, with a different frame and electrical frequency. The rated frequency in the motor table is the inverter output requirement, not a direct mains connection instruction. Start with the driven shaft’s operating point and then check the motor, inverter and installation as a set.
Individual 380 V rows from the TYCP manual. All three use the catalogue’s WN90T-22G-4 drive pairing; this does not make their motor settings or mechanical interfaces identical.
| Full model | Rated operating point | Rated motor current |
|---|---|---|
| TYCP180L-8-30 | 3,000 rpm; 200 Hz; 70.03 Nm | 36.69 A |
| TYCP180L-8-15 | 1,500 rpm; 100 Hz; 140.1 Nm | 37.15 A |
| TYCP200L2-8-10 | 1,000 rpm; 66.67 Hz; 210.1 Nm | 36.80 A |
For the B3 / IC411 drawing, dimensions are in millimetres. Check the complete selected assembly drawing before machining a base or coupling.
| Frame 180L: the 3,000 and 1,500 rpm examples | The dimension table gives shaft diameter 48, shaft extension 110, key width 14, foot-hole spacing A × B of 279 × 279 and overall length L of 715. |
|---|---|
| Frame 200L: the 1,000 rpm example | The frame 200L entry changes shaft diameter to 55, key width to 16, foot-hole spacing to 318 × 305 and overall length to 770; the shaft extension remains 110. Keeping the same power rating therefore does not preserve the existing coupling bore or base-hole pattern. |
The eight-pole examples are rated at 200, 100 and 66.67 Hz respectively. The matched WN90T table lists three-phase AC 380 V ±15% input and an output-frequency capability of 0–600 Hz. That drive capability is not permission to run every TYCP at 600 Hz or beyond its mechanical speed limit.
WN90T-22G-4 is listed with 46 A rated input current and 45 A rated output current. Those are drive entries; the motor currents are the separate values above. Give the supplier the load cycle and any overload requirement rather than selecting only by the common 22 kW label.
In the 3,000 rpm table, the 45 kW TYCP225M-8-30 is IC411 and the 55 kW TYCP250M-8-30 is IC416. The 1,500 rpm table lists IC411 for its 55 kW entry. Ask for the independent fan supply, airflow direction and interlock details where IC416 is selected; power alone does not determine the cooling arrangement.
The manual states IP55, while the collected product webpage contains both IP54 and IP55. Record the required enclosure rating on the accepted motor sheet rather than silently choosing the more protective value. The manual’s efficiency-class statement also does not replace model-specific procurement documentation.
CATALOGUE OVERVIEW
Wannan’s TYCP is an inverter-driven permanent-magnet synchronous motor family covering 0.55–375 kW and frames 80–355 in the collected catalogue. The source specifies 380 V, class F insulation and S1 duty, with IC411 or IC416 cooling depending on configuration. It identifies machine tools, fans, pumps and transport machinery as applications. The page contains differing IP54 and IP55 statements, so the enclosure rating must be confirmed for the selected model. Ask for the matched drive and torque-speed data as part of the quotation.
Specifications describe a series range; confirm which ratings apply together to the quoted model.
Confirm mounting and shaft dimensions against the drawing for the quoted configuration.
Keep your sourcing team on the same page.
We use cookies to keep this site working and measure website usage. Cookie & privacy details